ADL500 • Quick installation guide - Specifications and connection
67
Step 4 – Setting mechanical system data
STARTUP WIZARD
Set mechanical data?
E=Yes
Down=Next
E
01/09
PAR:
11002
Travel unit sel
Hz
Value:
0
Available selections:
0 Hz (output frequency)
1 m/s (cabin speed, depends on the mechanical constant )
2 Rpm (motor shaft speed )
3 USCS (US unit of measure: fpm, ft/s
2
, ft/s
3
)
02/09
PAR:
11006
Cabin speed
1.00
m/s
Def:
1.0
Range: 0 ... 10
03/09
PAR:
11010
Gearbox ratio
45.000
Def:
45.000
Range: 1 ... 200
04/09
PAR:
11164
Rope ratio
1
Def:
1
Range: 1 ... 40
05/09
PAR:
11012
Pulley diameter
0.600
m
Def:
0.600
Range: 0 ... 5
06/09
PAR:
11150
Car weight
400
kg
Def:
400
Range: 0 ... 10000
07/09
PAR:
11052
Counter weight
1000
kg
Def:
1000
Range: 0 ... 10000
08/09
PAR:
11154
Load weight
450
kg
Def:
450
Range: 0 ... 100,000
09/09
PAR:
11156
Rope weight
20
kg
Def:
20
Range: 0 ... 10000
At the end of the procedure proceed to next step.
Содержание ADL500
Страница 95: ......