ADL500 • Quick installation guide - Specifications and connection
73
These data are lost if the device is switched off. To save the motor data follow the procedure described in step 8.
At the end of the procedure proceed to next step.
Step 4 – Setting mechanical system data
STARTUP WIZARD
Set mechanical data?
E=Yes
Down=Next
E
01/09
PAR:
11002
Travel unit sel
Hz
Value:
0
Available selections:
0 Hz (output frequency)
1 m/s (cabin speed, depends on the mechanical constant )
2 Rpm (motor shaft speed )
3 USCS (US unit of measure: fpm, ft/s
2
, ft/s
3
)
02/09
PAR:
11006
Cabin speed
1.00
m/s
Def:
1.0
Range: 0 ... 10
03/09
PAR:
11010
Gearbox ratio
45.000
Def:
45.000
Range: 1 ... 200
04/09
PAR:
11164
Rope ratio
1
Def:
1
Range: 1 ... 40
05/09
PAR:
11012
Pulley diameter
0.600
m
Def:
0.600
Range: 0 ... 5
06/09
PAR:
11150
Car weight
400
kg
Def:
400
Range: 0 ... 10000
07/09
PAR:
11052
Counter weight
1000
kg
Def:
1000
Range: 0 ... 10000
08/09
PAR:
11154
Load weight
450
kg
Def:
450
Range: 0 ... 100,000
09/09
PAR:
11156
Rope weight
20
kg
Def:
20
Range: 0 ... 10000
At the end of the procedure proceed to next step.