80
ADL500 • Quick installation guide - Specifications and connection
Index
Error message shown
on the display
Sub-code
Description
56
Load par def plc
Condition:
this can occur during loading of the parameter database saved in the Flash memory of the MDPLC application
it is normal if it appears the first time the drive is switched on, after downloading a new application. If this message appears when the drive is already in
use it means there has been a problem in the parameter database saved in the Flash memory.
If this message appears the drive automatically runs the Load default command.
0001H-1
The database saved is not valid
Solution:
Set the parameters to the desired value and run Save parameter.
57
Key failed
Condition:
this can occur at drive power-on if the wrong enabling key is entered for a given firmware function
0001H-1
Incorrect PLC key. PLC application not available.
Solution:
Contact Gefran to request the key to enable the desired firmware function.
58
Encoder error
Condition:
this condition may occur when the drive is powered during encoder setup each time parameter 552
Regulation mode
is set.
100H-256
Cause
: An error occurred during setup; the information received from the encoder is not reliable. If the encoder is used for feedback the
Speed fbk loss
alarm is also generated.
Solution:
Take the recommended action for the
Speed fbk loss
alarm.
200H-512
Cause
: The firmware on the optional encoder card is incompatible with that on the regulation card. The information received from the
encoder is not reliable
Solution:
Contact Gefran in order to update the firmware on the optional encoder card.
59
Opt cfg change
Condition:
an optional card has been removed with respect to the configuration present when the last
Save parameters
command was executed or there
is a fault on the optional card or on the regulation card.
Solution:
If the user has removed the card on purpose, execute
Save parameters
. If the user has not removed the card, identify and replace the faulty
card.
10.1.1 EFC application alarms
Index
Error message shown
on the display
Description
33
Cont feedback
Condition
: The contactor feedback signal does not match its command.
Solution
: Check contactor feedback wiring, check logic status of feedback input to drive, increase hold off time (PAR 11202).
34
Brake Feedback
Condition
: The brake feedback signal does not match its command.
Solution
: Check brake feedback wiring, check logic status of feedback input to drive, increase hold off time (PAR 11206).
35
Door Feedback
Condition
: The door feedback signal does not match its command.
Solution
: Check door feedback wiring, check logic status of feedback input to drive, increase hold off time (PAR 11212).
36
Brake Failure
Condition
: Exceeding the Threshold A3 (PAR 11270).
Solution
: Reset alarm using the reset parameter (PAR 11268), check that brake is intact, increase threshold (PAR 11270).
37
Safe Brake Test
Condition
: Brake force test failed.
Solution
: Check that brake is intact, increase the maximum deviation threshold (PAR 11840).
38
Speed limit
Condition
: Speed limitation warning to ensure stopping, enabling the DISTANCE function.
Solution
: Check multi-speed selected for current distance.
39
Up/low limit
Condition
: Speed threshold exceeded in limit switches zone (sensors installed at the top and bottom of the lift/elevator shaft).
Solution
: Check speed set in limit switches zone, change speed limit (PAR 11216).
40
Lift ext fault
Condition
: External alarm signal triggered (PAR 11258).
Solution
: Check causes enabling external alarm signal, increase hold off time (PAR 11266).
41
Battery Low
Condition
: Battery monitoring alarm triggered.
Solution
: Check whether battery is properly connected to drive.