CHAPTER 7: MODBUS COMMUNICATIONS
MODBUS MEMORY MAP
PQM POWER QUALITY METER – INSTRUCTION MANUAL
7–51
TRACE
MEMORY
0B80
Trace Memory Usage
---
---
---
F37
N/A
0B81
Trace Memory Trigger Flag
---
---
---
F113
N/A
0B82
Trace Memory Trigger Counter
---
---
---
F1
N/A
0B83
Total Trace Memory Triggers
---
---
---
F1
N/A
0B88
Trigger Cause - Trace 1
---
---
---
F41
N/A
0B89
Time - Hours/Minutes - Trace 1
---
---
---
F22
N/A
0B8A
Time - Seconds - Trace 1
---
---
---
F23
N/A
0B8B
Date - Month/Day - Trace 1
---
---
---
F24
N/A
0B8C
Date - Year - Trace 1
---
---
---
F25
N/A
0B8D
Trigger Sample Number 1
---
---
---
F1
N/A
0B8E
Frequency 1
---
---
0.01 x Hz
F1
N/A
0B98
Trigger Cause - Trace 2
---
---
---
F41
N/A
0B99
Time - Hours/Minutes - Trace 2
---
---
---
F22
N/A
0B9A
Time - Seconds - Trace 2
---
---
---
F23
N/A
0B9B
Date - Month/Day - Trace 2
---
---
---
F24
N/A
0B9C
Date - Year - Trace 2
---
---
---
F25
N/A
0B9D
Trigger Sample Number 2
---
---
---
F1
N/A
0B9E
Frequency 2
---
---
0.01 x Hz
F1
N/A
0BA8
Trigger Cause - Trace 3
---
---
---
F41
N/A
0BA9
Time - Hours/Minutes - Trace 3
---
---
---
F22
N/A
0BAA
Time - Seconds - Trace 3
---
---
---
F23
N/A
0BAB
Date - Month/Day - Trace 3
---
---
---
F24
N/A
0BAC
Date - Year - Trace 3
---
---
---
F25
N/A
0BAD
Trigger Sample Number 3
---
---
---
F1
N/A
0BAE
Frequency 3
---
---
0.01xHz
F1
N/A
0BB8
Trace Memory Waveform Selection
---
---
---
F40
N/A
0BB9
0BBA
Waveform Scale Factor (high)
Waveform Scale Factor (low)
---
---
A/
Vx10000
F3
N/A
0BBB
Data Buffer 1
---
---
ADCcount
s/2
F2
N/A
0BBC
Data Buffer 2
---
---
ADCcount
s/2
F2
N/A
to
↓
↓
↓
↓
↓
↓
0DF9
Data Buffer 575
---
---
ADCcount
s/2
F2
N/A
0DFA
Data Buffer 576
---
---
ADCcount
s/2
F2
N/A
0DFB
Reserved
to
↓
↓
↓
↓
↓
↓
0DFF
Reserved
0E00
Invalid Serial Number Flag
---
---
---
F117
N/A
Table 7–10: PQM Memory Map (Sheet 35 of 55)
GROUP
ADDR
(HEX)
DESCRIPTION
RANGE
STEP
VALUE
UNITS and
SCALE
FORMAT
FACTORY
DEFAULT
Notes:* Data type depends on the Command Operation Code.** Any valid Actual Values or Setpoints address.
*** Maximum Setpoint value represents “OFF”.**** Minimum Setpoint value represents “OFF”.
***** Maximum Setpoint value represents “UNLIMITED”.****** Applicable to older revisions with VFD display only
Содержание Multilin PQM
Страница 3: ...Courtesy of NationalSwitchgear com ...
Страница 4: ...Courtesy of NationalSwitchgear com ...
Страница 10: ...TOC VI PQM POWER QUALITY METER INSTRUCTION MANUAL TABLE OF CONTENTS Courtesy of NationalSwitchgear com ...
Страница 348: ...I 10 PQM POWER QUALITY METER INSTRUCTION MANUAL INDEX Courtesy of NationalSwitchgear com ...