GE Multilin
G30 Generator Protection System
B-75
APPENDIX B
B.4 MEMORY MAPPING
B
151
Phase Overvoltage 1
152
Phase Overvoltage 2
153
Phase Overvoltage 3
156
Neutral Overvoltage 1
157
Neutral Overvoltage 2
158
Neutral Overvoltage 3
209
Transformer Percent Differential
210
Volt per Hertz 1
211
Volt per Hertz 2
214
Sensitive Directional Power 1
215
Sensitive Directional Power 2
222
Split Phase Protection
224
SRC1 VT Fuse Failure
225
SRC2 VT Fuse Failure
226
SRC3 VT Fuse Failure
227
SRC4 VT Fuse Failure
232
SRC1 50DD (Disturbance Detection)
233
SRC2 50DD (Disturbance Detection)
234
SRC3 50DD (Disturbance Detection)
235
SRC4 50DD (Disturbance Detection)
246
CT Failure
272
CT Fail 1
273
CT Fail 2
274
CT Fail 3
275
CT Fail 4
296
Accidental Energization
300
Loss Of Excitation
312
Synchrocheck 1
313
Synchrocheck 2
314
Synchrocheck 3
315
Synchrocheck 4
330
Third harmonic neutral undervoltage
336
Setting Group
337
Reset
344
Overfrequency 1
345
Overfrequency 2
346
Overfrequency 3
347
Overfrequency 4
352
Underfrequency 1
353
Underfrequency 2
354
Underfrequency 3
355
Underfrequency 4
356
Underfrequency 5
357
Underfrequency 6
388
Selector switch 1
389
Selector switch 2
390
Control pushbutton 1
391
Control pushbutton 2
392
Control pushbutton 3
393
Control pushbutton 4
394
Control pushbutton 5
395
Control pushbutton 6
396
Control pushbutton 7
Bitmask
Element
400
FlexElement 1
401
FlexElement 2
402
FlexElement 3
403
FlexElement 4
404
FlexElement 5
405
FlexElement 6
406
FlexElement 7
407
FlexElement 8
408
FlexElement 9
409
FlexElement 10
410
FlexElement 11
411
FlexElement 12
412
FlexElement 13
413
FlexElement 14
414
FlexElement 15
415
FlexElement 16
420
Non-volatile Latch 1
421
Non-volatile Latch 2
422
Non-volatile Latch 3
423
Non-volatile Latch 4
424
Non-volatile Latch 5
425
Non-volatile Latch 6
426
Non-volatile Latch 7
427
Non-volatile Latch 8
428
Non-volatile Latch 9
429
Non-volatile Latch 10
430
Non-volatile Latch 11
431
Non-volatile Latch 12
432
Non-volatile Latch 13
433
Non-volatile Latch 14
434
Non-volatile Latch 15
435
Non-volatile Latch 16
530
Frequency Rate of Change 1
531
Frequency Rate of Change 2
532
Frequency Rate of Change 3
533
Frequency Rate of Change 4
544
Digital Counter 1
545
Digital Counter 2
546
Digital Counter 3
547
Digital Counter 4
548
Digital Counter 5
549
Digital Counter 6
550
Digital Counter 7
551
Digital Counter 8
692
Digital Element 1
693
Digital Element 2
694
Digital Element 3
695
Digital Element 4
696
Digital Element 5
697
Digital Element 6
698
Digital Element 7
699
Digital Element 8
700
Digital Element 9
Bitmask
Element
Содержание G30
Страница 10: ...x G30 Generator Protection System GE Multilin TABLE OF CONTENTS ...
Страница 30: ...1 20 G30 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 414: ...5 274 G30 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 456: ...8 2 G30 Generator Protection System GE Multilin 8 1 DIRECTIONAL PRINCIPLE 8 THEORY OF OPERATION 8 ...
Страница 470: ...9 14 G30 Generator Protection System GE Multilin 9 1 SETTING EXAMPLE 9 APPLICATION OF SETTINGS 9 ...
Страница 484: ...11 12 G30 Generator Protection System GE Multilin 11 6 DISPOSAL 11 MAINTENANCE 11 ...
Страница 512: ...A 28 G30 Generator Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 620: ...B 108 G30 Generator Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 666: ...E 10 G30 Generator Protection System GE Multilin E 1 IEC 60870 5 104 APPENDIX E E ...
Страница 678: ...F 12 G30 Generator Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 687: ...GE Multilin G30 Generator Protection System H 7 APPENDIX H H 2 ABBREVIATIONS H Z Impedance Zone ...