A-8
G30 Generator Protection System
GE Multilin
A.1 PARAMETER LISTS
APPENDIX A
A
8070
SRC 1 Va Harm[7]
%
Source 1 phase A voltage seventh harmonic
8071
SRC 1 Va Harm[8]
%
Source 1 phase A voltage eighth harmonic
8072
SRC 1 Va Harm[9]
%
Source 1 phase A voltage ninth harmonic
8073
SRC 1 Va Harm[10]
%
Source 1 phase A voltage tenth harmonic
8074
SRC 1 Va Harm[11]
%
Source 1 phase A voltage eleventh harmonic
8075
SRC 1 Va Harm[12]
%
Source 1 phase A voltage twelfth harmonic
8076
SRC 1 Va Harm[13]
%
Source 1 phase A voltage thirteenth harmonic
8077
SRC 1 Va Harm[14]
%
Source 1 phase A voltage fourteenth harmonic
8078
SRC 1 Va Harm[15]
%
Source 1 phase A voltage fifteenth harmonic
8079
SRC 1 Va Harm[16]
%
Source 1 phase A voltage sixteenth harmonic
8080
SRC 1 Va Harm[17]
%
Source 1 phase A voltage seventeenth harmonic
8081
SRC 1 Va Harm[18]
%
Source 1 phase A voltage eighteenth harmonic
8082
SRC 1 Va Harm[19]
%
Source 1 phase A voltage nineteenth harmonic
8083
SRC 1 Va Harm[20]
%
Source 1 phase A voltage twentieth harmonic
8084
SRC 1 Va Harm[21]
%
Source 1 phase A voltage twenty-first harmonic
8085
SRC 1 Va Harm[22]
%
Source 1 phase A voltage twenty-second harmonic
8086
SRC 1 Va Harm[23]
%
Source 1 phase A voltage twenty-third harmonic
8087
SRC 1 Va Harm[24]
%
Source 1 phase A voltage twenty-fourth harmonic
8088
SRC 1 Va Harm[25]
%
Source 1 phase A voltage twenty-fifth harmonic
8089
SRC 1 Vb THD
%
Source 1 phase B voltage total harmonic distortion (THD)
8090
SRC 1 Vb Harm[2]
%
Source 1 phase B voltage second harmonic
8091
SRC 1 Vb Harm[3]
%
Source 1 phase B voltage third harmonic
8092
SRC 1 Vb Harm[4]
%
Source 1 phase B voltage fourth harmonic
8093
SRC 1 Vb Harm[5]
%
Source 1 phase B voltage fifth harmonic
8094
SRC 1 Vb Harm[6]
%
Source 1 phase B voltage sixth harmonic
8095
SRC 1 Vb Harm[7]
%
Source 1 phase B voltage seventh harmonic
8096
SRC 1 Vb Harm[8]
%
Source 1 phase B voltage eighth harmonic
8097
SRC 1 Vb Harm[9]
%
Source 1 phase B voltage ninth harmonic
8098
SRC 1 Vb Harm[10]
%
Source 1 phase B voltage tenth harmonic
8099
SRC 1 Vb Harm[11]
%
Source 1 phase B voltage eleventh harmonic
8100
SRC 1 Vb Harm[12]
%
Source 1 phase B voltage twelfth harmonic
8101
SRC 1 Vb Harm[13]
%
Source 1 phase B voltage thirteenth harmonic
8102
SRC 1 Vb Harm[14]
%
Source 1 phase B voltage fourteenth harmonic
8103
SRC 1 Vb Harm[15]
%
Source 1 phase B voltage fifteenth harmonic
8104
SRC 1 Vb Harm[16]
%
Source 1 phase B voltage sixteenth harmonic
8105
SRC 1 Vb Harm[17]
%
Source 1 phase B voltage seventeenth harmonic
8106
SRC 1 Vb Harm[18]
%
Source 1 phase B voltage eighteenth harmonic
8107
SRC 1 Vb Harm[19]
%
Source 1 phase B voltage nineteenth harmonic
8108
SRC 1 Vb Harm[20]
%
Source 1 phase B voltage twentieth harmonic
8109
SRC 1 Vb Harm[21]
%
Source 1 phase B voltage twenty-first harmonic
8110
SRC 1 Vb Harm[22]
%
Source 1 phase B voltage twenty-second harmonic
8111
SRC 1 Vb Harm[23]
%
Source 1 phase B voltage twenty-third harmonic
8112
SRC 1 Vb Harm[24]
%
Source 1 phase B voltage twenty-fourth harmonic
8113
SRC 1 Vb Harm[25]
%
Source 1 phase B voltage twenty-fifth harmonic
8114
SRC 1 Vc THD
%
Source 1 phase C voltage total harmonic distortion (THD)
8115
SRC 1 Vc Harm[2]
%
Source 1 phase C voltage second harmonic
8116
SRC 1 Vc Harm[3]
%
Source 1 phase C voltage third harmonic
Table A–1: FLEXANALOG DATA ITEMS (Sheet 8 of 27)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Содержание G30
Страница 10: ...x G30 Generator Protection System GE Multilin TABLE OF CONTENTS ...
Страница 30: ...1 20 G30 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 414: ...5 274 G30 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 456: ...8 2 G30 Generator Protection System GE Multilin 8 1 DIRECTIONAL PRINCIPLE 8 THEORY OF OPERATION 8 ...
Страница 470: ...9 14 G30 Generator Protection System GE Multilin 9 1 SETTING EXAMPLE 9 APPLICATION OF SETTINGS 9 ...
Страница 484: ...11 12 G30 Generator Protection System GE Multilin 11 6 DISPOSAL 11 MAINTENANCE 11 ...
Страница 512: ...A 28 G30 Generator Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 620: ...B 108 G30 Generator Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 666: ...E 10 G30 Generator Protection System GE Multilin E 1 IEC 60870 5 104 APPENDIX E E ...
Страница 678: ...F 12 G30 Generator Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 687: ...GE Multilin G30 Generator Protection System H 7 APPENDIX H H 2 ABBREVIATIONS H Z Impedance Zone ...