2-14
G30 Generator Protection System
GE Multilin
2.2 ORDER CODES
2 PRODUCT DESCRIPTION
2
The order codes for the reduced size vertical mount units with the process bus module are shown below.
Table 2–7: G30 ORDER CODES (REDUCED SIZE VERTICAL UNITS WITH PROCESS BUS)
G30
-
*
**
- *
*
* - F
**
- H
**
- M
**
-
P/R
**
Reduced Size Vertical Mount (see note regarding P/R slot below)
BASE UNIT
G30
|
|
|
|
|
|
|
|
|
Base Unit
CPU
T
|
|
|
|
|
|
|
|
RS485 and Three Multi-mode fiber 100Base-FX (SFP with LC)
U
|
|
|
|
|
|
|
|
RS485 and Two Multi-mode fiber 100Base-FX (SFP with LC), One 10/100Base-T (SFP with RJ45)
V
|
|
|
|
|
|
|
|
RS485 and Three 10/100Base-T (SFP with RJ45)
SOFTWARE
00
|
|
|
|
|
|
|
No Software Options
01
|
|
|
|
|
|
|
Ethernet Global Data (EGD)
03
|
|
|
|
|
|
|
IEC 61850
04
|
|
|
|
|
|
|
Ethernet Global Data (EGD) and IEC 61850
A0
|
|
|
|
|
|
|
CyberSentry Lvl 1
A1
|
|
|
|
|
|
|
CyberSentry Lvl 1 and Ethernet Global Data (EGD)
A3
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850
A4
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850 and Ethernet Global Data (EGD)
B0
|
|
|
|
|
|
|
IEEE 1588
B1
|
|
|
|
|
|
|
IEEE 1588 and Ethernet Global Data (EGD)
B3
|
|
|
|
|
|
|
IEEE 1588 and IEC 61850
B4
|
|
|
|
|
|
|
IEEE 1588 and IEC 61850 and Ethernet Global Data (EGD)
C0
|
|
|
|
|
|
|
Parallel Redundancy Protocol (PRP)
C1
|
|
|
|
|
|
|
PRP and Ethernet Global Data
C3
|
|
|
|
|
|
|
PRP and IEC 61850
C4
|
|
|
|
|
|
|
PRP, Ethernet Global Data, and IEC 61850
D0
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1
D1
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and Ethernet Global Data (EGD)
D3
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850
D4
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and Ethernet Global Data (EGD)
E0
|
|
|
|
|
|
|
IEEE 1588 and PRP
E1
|
|
|
|
|
|
|
IEEE 1588, PRP, and Ethernet Global Dada
E3
|
|
|
|
|
|
|
IEEE 1588, PRP, and IEC 61850
E4
|
|
|
|
|
|
|
IEEE 1588, PRP, Ethernet Global Data, and IEC 61850
F0
|
|
|
|
|
|
|
PRP and CyberSentry Lvl1
F1
|
|
|
|
|
|
|
PRP, CyberSentry Lvl1, and Ethernet Global Data
F3
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, and IEC 61850
F4
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
G0
|
|
|
|
|
|
|
IEEE 1588, PRP, and CyberSentry Lvl 1
G1
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, Ethernet Global Data
G3
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850
G4
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
J0
|
|
|
|
|
|
|
IEC 60870-5-103
J1
|
|
|
|
|
|
|
IEC 60870-5-103 + EGD
J3
|
|
|
|
|
|
|
IEC 60870-5-103 + IEC 61850
J4
|
|
|
|
|
|
|
IEC 60870-5-103 + EGD + IEC 61850
K0
|
|
|
|
|
|
|
IE PRP + IEC 60870-5-103
K1
|
|
|
|
|
|
|
IE PRP + IEC 60870-5-103 + EGD
K3
|
|
|
|
|
|
|
IE PRP + IEC 60870-5-103 + IEC 61850
K4
|
|
|
|
|
|
|
IE PRP + IEC 60870-5-103 + EGD + IEC 61850
L0
|
|
|
|
|
|
|
IEC 60870-5-103 + IE PRP + CyberSentry Lvl 1
L1
|
|
|
|
|
|
|
IEC 60870-5-103 + IE PRP + CyberSentry Lvl 1 + EGD
L3
|
|
|
|
|
|
|
IEC 60870-5-103 + IE PRP + CyberSentry Lvl 1 + IEC 61850
L4
|
|
|
|
|
|
|
IEC 60870-5-103 + IE PRP + CyberSentry Lvl 1 + EGD + IEC 61850
MOUNT/COATING
V
|
|
|
|
|
|
Vertical (3/4 rack)
B
|
|
|
|
|
|
Vertical (3/4 rack) with harsh environmental coating
FACEPLATE/ DISPLAY
C
|
|
|
|
|
English display
D
|
|
|
|
|
French display
R
|
|
|
|
|
Russian display
A
|
|
|
|
|
Chinese display
K
|
|
|
|
|
Enhanced front panel with English display
M
|
|
|
|
|
Enhanced front panel with French display
Q
|
|
|
|
|
Enhanced front panel with Russian display
U
|
|
|
|
|
Enhanced front panel with Chinese display
L
|
|
|
|
|
Enhanced front panel with English display and user-programmable pushbuttons
N
|
|
|
|
|
Enhanced front panel with French display and user-programmable pushbuttons
T
|
|
|
|
|
Enhanced front panel with Russian display and user-programmable pushbuttons
V
|
|
|
|
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
W
|
|
|
|
|
Enhanced front panel with Turkish display
Y
|
|
|
|
|
Enhanced front panel with Turkish display and user-programmable pushbuttons
I
|
|
|
|
|
Enhanced front panel with German display
J
|
|
|
|
|
Enhanced front panel with German display and user-programmable pushbuttons
POWER SUPPLY
H
|
|
|
|
125 / 250 V AC/DC power supply
L
|
|
|
|
24 to 48 V (DC only) power supply
PROCESS BUS MODULE
|
81
|
|
Eight-port digital process bus module
DIGITAL INPUTS/OUTPUTS
XX
XX
XX
No Module
4A
4 Solid-State (no monitoring) MOSFET outputs
4B
4 Solid-State (voltage with optional current) MOSFET outputs
4C
4 Solid-State (current with optional voltage) MOSFET outputs
4D
16 digital inputs with Auto-Burnishing (maximum of three modules within a case)
4L
14 Form-A (no monitoring) Latching outputs
67
8 Form-A (no monitoring) outputs
6A
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 digital inputs
6B
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 digital inputs
6C
8 Form-C outputs
6D
16 digital inputs
6E
4 Form-C outputs, 8 digital inputs
6F
8 Fast Form-C outputs
6G
4 Form-A (voltage with optional current) outputs, 8 digital inputs
6H
6 Form-A (voltage with optional current) outputs, 4 digital inputs
6K
4 Form-C and 4 Fast Form-C outputs
6L
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 digital inputs
6M
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 digital inputs
6N
4 Form-A (current with optional voltage) outputs, 8 digital inputs
6P
6 Form-A (current with optional voltage) outputs, 4 digital inputs
6R
2 Form-A (no monitoring) and 2 Form-C outputs, 8 digital inputs
6S
2 Form-A (no monitoring) and 4 Form-C outputs, 4 digital inputs
6T
4 Form-A (no monitoring) outputs, 8 digital inputs
6U
6 Form-A (no monitoring) outputs, 4 digital inputs
6V
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 digital inputs
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
For the last module, slot P is used for digital
input/output modules; slot R is used for inter-relay
communications modules.
2A
C37.94SM, 1300 nm single-mode, ELED, 1 channel single-mode
2B
C37.94SM, 1300 nm single-mode, ELED, 2 channel single-mode
2E
Bi-phase, single channel
2F
Bi-phase, dual channel
2G
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
2I
Channel 1 - IEEE C37.94, MM, 64/128 kbps; Channel 2 - 1300 nm, single-mode, Laser
2J
Channel 1 - IEEE C37.94, MM, 64/128 kbps; Channel 2 - 1550 nm, single-mode, Laser
72
1550 nm, single-mode, Laser, 1 Channel
73
1550 nm, single-mode, Laser, 2 Channel
74
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, Laser
75
Channel 1 - G.703; Channel 2 - 1550 nm, single-mode Laser
76
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A
820 nm, multimode, LED, 1 Channel
7B
1300 nm, multimode, LED, 1 Channel
7C
1300 nm, single-mode, ELED, 1 Channel
7D
1300 nm, single-mode, Laser, 1 Channel
7E
Channel 1 - G.703; Channel 2 - 820 nm, multimode
7F
Channel 1 - G.703; Channel 2 - 1300 nm, multimode
7G
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H
820 nm, multimode, LED, 2 Channels
7I
1300 nm, multimode, LED, 2 Channels
7J
1300 nm, single-mode, ELED, 2 Channels
7K
1300 nm, single-mode, Laser, 2 Channels
7L
Channel 1 - RS422; Channel 2 - 820 nm, multimode, LED
7M
Channel 1 - RS422; Channel 2 - 1300 nm, multimode, LED
7N
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
7P
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, Laser
Содержание G30
Страница 10: ...x G30 Generator Protection System GE Multilin TABLE OF CONTENTS ...
Страница 30: ...1 20 G30 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 414: ...5 274 G30 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 456: ...8 2 G30 Generator Protection System GE Multilin 8 1 DIRECTIONAL PRINCIPLE 8 THEORY OF OPERATION 8 ...
Страница 470: ...9 14 G30 Generator Protection System GE Multilin 9 1 SETTING EXAMPLE 9 APPLICATION OF SETTINGS 9 ...
Страница 484: ...11 12 G30 Generator Protection System GE Multilin 11 6 DISPOSAL 11 MAINTENANCE 11 ...
Страница 512: ...A 28 G30 Generator Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 620: ...B 108 G30 Generator Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 666: ...E 10 G30 Generator Protection System GE Multilin E 1 IEC 60870 5 104 APPENDIX E E ...
Страница 678: ...F 12 G30 Generator Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 687: ...GE Multilin G30 Generator Protection System H 7 APPENDIX H H 2 ABBREVIATIONS H Z Impedance Zone ...