Concord 4 Series Systems
5
•
Bus A and B:
Input and output that provides communication between bus devices and the
panel.
•
Siren Driver:
Output that can drive an 8-ohm load and provides intrusion and fire alarm
sounds for partition 1. 6 watts max.
•
2 Onboard Outputs:
Can be used to activate other signalling devices based on system
events.
-Out 1 is a 9 to 14 VDC source output, limited to 1.0 amp max.
-Out 2 is an open-collector output, rated up to 14 VDC, 300mA max.
•
Microphone Input:
Input used for 2-way audio when used in conjunction with the Interro-
gator 200 Audio Verification Module.
•
8 Supervised Hardwire Zones:
Inputs for various hardwired detectors. Zone 8 can be set
up in programming to accept 2-wire smoke detectors. It sources 9 to 14 VDC, 90mA max.
•
Built-In RF Receiver:
Allows use of up to 96 or 32 319.5 MHz. crystal and/or SAW Learn
Mode wireless sensors and touchpads.
•
Phone Line Connection:
Allows panel to communicate with central monitoring station and/
or pagers.
Note
The total current sourced from all terminals cannot exceed 1 amp.
SuperBus 2000 Touchpads
The following touchpads can be used for installer/user programming and system operation.
•
SuperBus 2000 2x16 LCD Touchpad
•
SuperBus 2000 2x20 LCD Touchpad
•
SuperBus 2000 2x20 VFD Touchpad
•
SuperBus 2000 ATP 1000 Touchpad
•
SuperBus 2000 ATP 2100 Touchpad
•
SuperBus 2000 ATP 2600 Touchpad
•
SuperBus 2000 GTS 50
The following touchpads can be used only for installer quick programming, system operation and
user programming.
•
SuperBus 2000 Fixed Display Touchpad
SuperBus 2000 RF Transceiver
The transceiver can be used to receive signals from sensors and touchpad that may be on the
fringe of panel reception. The transceiver is compatible with all 319.5 MHz. crystal and SAW
Learn Mode wireless sensors and touchpads.
SuperBus 2000 RF Receiver
The receiver can be used to receive signals from sensors and touchpad that may be on the fringe
of panel reception. The receiver is compatible with all 319.5 MHz. crystal and SAW Learn Mode
wireless sensors and touchpads.
Note
If installing this module, the Antenna Tamper feature must be turned off.
Power Line Carrier Transformer
Using this transformer allows the use of X10 Powerhouse Lamp Modules for light control and
light activation during alarms.
SuperBus 2000 Voice Only Module
This module provides an output for a speaker that sounds system status and alarm voice mes-
sages.
SuperBus 2000 Phone Interface/Voice Module
This module allows system access and control using touch-tone telephones, on- or off-site. The
module includes an output for a speaker that sounds system status and alarm voice messages.