Concord 4 Series Systems
46
Two Trip Error
(06009)
Reporting-Global (Default = off)
This setting works with the Alarm Verify setting (see “Alarm Verify” later in this
section and Appendix B: Table B1 “Sensor Table Characteristics”). If Alarm Verify
is on, then the panel waits for a second sensor trip before sending an alarm.
Note
For UL Listed installations, the Two Trip Error feature must be set to off.
If Two Trip Error is also on and a second sensor trip
does not occur
within a 4-minute
time period, then the panel sends an error report to the central monitoring station.
To turn Two Trip Error off or on:
1. With the display showing
TWO
TRIP ERROR OFF/ON
(current set-
ting)
, press 1 (off) or 2 (on). The
display flashes the entered set-
ting.
2. Press # and the display shows the
new setting.
TP Panic RPT FMT
(06010)
Reporting-Global (Default = off)
This setting determines how the panel formats touchpad panic alarm
reports to the central station.
When this feature is turned on, touchpad panic alarms report using
the following 3-digit codes:
Auxiliary—597, Police—598, Fire—599
When turned off, touchpad panic alarms report using a 3-digit code
from 500 to 515, with the last 2 digits identifying the touchpad device
number.
To turn TP Panic RPT FMT off or on:
1. With the display showing
TP PANIC RPT FMT OFF/
ON
(current setting)
, press 1 (off) or 2 (on). The
display flashes the entered setting.
2. Press # and the display shows the new setting.
AC Failure
(06011)
Reporting-Global (Default = off)
When this setting is on, the panel reports to the central station at a
random time between 15 and 45 minutes after AC power to the
panel is lost. Making the report random helps prevent systems in a
power outage affected area from trying to report at the same time.
Note
If this feature and the Aux Power Fail feature are both on, the panel also
monitors for and reports an AC failure for the SuperBus 2000 2-Amp
Power Supply.
Note
For UL Listed installations, AC Failure must be set to on.
To turn AC Failure reports off or on:
1. With the display showing
AC
FAILURE
OFF
/
ON
(cur-
rent setting)
, press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
Receiver Failure
(06012)
Reporting-Global (Default = off)
When this setting is on, the panel reports a receiver failure under the
following conditions:
•
No wireless sensor signals have been received for two hours or
•
The receiver is being jammed with a constant signal.
Note
For UL Listed installations using wireless devices, Receiver Failure must
be set to on.
To turn Receiver Failure reports off or on:
1. With the display showing
RECEIVER FAILURE OFF/
ON
(current setting)
, press 1 (off) or 2 (on). The dis-
play flashes the entered setting.
2. Press # and the display shows the new setting.
RF Low Bat Rpt
(06013)
Reporting-Global (Default = weekly)
This setting determines whether the panel sends daily or weekly
low battery reports to the central monitoring station when a wireless
device is reporting a low battery condition to the panel.
To set RF Low Battery Report to daily or weekly:
1. With the display showing
RF LOW BAT RPT DAILY/
WEEKLY
(current setting)
, press 1 (daily) or 2
(weekly). The display flashes the entered setting.
2. Press # and the display shows the new setting.