Phone Test Freq.
(0303)
Timers-Global (Default = 7 days)
This setting determines how often the panel conducts the automatic phone
test (see “Auto Phone Test” under
PHONE OPTIONS—GLOBAL
). The sys-
tem can be set to perform an automatic phone test anywhere from every
day to every 255 days.
Note
For UL 1610 & 1635 listed installations, this feature must be set to 1.
To set the Phone Test Freq:
1. With the display showing
PHONE TEST FREQ
nnn DAYS
(current setting)
, enter the number
of days (1–255). The display flashes the
entered setting.
2. Press # and the display shows the new setting.
Next Phone Test
(0304)
Timers-Global (Default = 7 days)
This setting is used by the Auto Phone Test feature (see
PHONE
OPTIONS—GLOBAL
) to determine when the next automatic phone test
should occur. This setting should be the same as, or less than, the Phone
Test Freq. setting.
Note
For UL 1610 & 1635 listed installations, this feature must be set to 1.
To set the Next Phone Test:
1. With the display showing
NEXT PHONE TEST
nnn DAYS
(current setting)
, enter the number
of days (1–255). The display flashes the
entered setting.
2. Press # and the display shows the new setting.
Output Trip Time
(0305)
Timers-Global (Default = 4 sec.)
This setting determines how long outputs are activated
when tripped (if they are configured for a momentary
response).
To set the Output Trip Time:
1. With the display showing
OUTPUT TRIP TIME nn SECS
(current
setting)
, enter the number of seconds (1–12). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
Activity Timeout
(0306)
Timers-Global (Default = 24 hours)
This setting determines when the system sends a “no activity” report.
The panel can be set to wait from 1–42 hours. If no user interaction or
device activation occurs in that time, the panel sends a report to the cen-
tral station.
To set the Activity Timeout:
1. With the display showing
ACTIVITY TIMEOUT
nn HOURS
(current
setting), enter the number
of hours (1–42). The display flashes the
entered setting.
2. Press # and the display shows the new setting.
Daylight Saving
(0307)
Timers-Global (Default = on)
When this setting is on, the panel clock automatically adjusts for daylight
saving time changes.
To turn Daylight Saving off or on:
1. With the display showing
DAYLIGHT SAVING
OFF/ON
(current setting)
, press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new setting.