Concord 4 Series Systems
91
Cross-Zoning
Note
Cross-Zoning is not recom-
mended for exit/entry zones.
Each zone has the ability to
individually protect the
intended area. (e.g. motion
detector patterns overlap).
Cross-Zone (Alarm Verify) refers to two different Group 10-20 sensors that must be tripped
within four minutes of each other to report an alarm to the central station. The diagram in the fig-
ure below shows the path of a person walking from the kitchen to the living room. When the per-
son is detected walking through the kitchen, the motion sensor in the kitchen is tripped, sounding
a local alarm. If motion is detected by the living room motion sensor within four minutes, an
alarm report will be sent to the central station.
26
Fire
24-hour fire, rate-of-rise heat, and smoke sensors.
Fire
Instant
√
√
√
1, 2, 3
27
Output Module
Hardwire Output Module (HOM) lamp control or other
customer feature. ‡
Silent
Instant
√
√
1, 2, 3
28
Output Module
HOM, PIR motion sensor, sound sensor or pressure
mat. ‡
Silent
Instant
√
1, 2, 3
29
Auxiliary
Freeze sensor.
Auxiliary Instant
√
√
√
1, 2, 3
32
Output Module
HOM, PIR motion sensor, sound sensor or pressure
mat.‡
Silent
Instant
33
Siren
Wireless Siren Supervision. ‡
Silent
Instant
√
√
1, 2, 3
34
Gas
Carbon monoxide (CO) Gas Detectors ‡
Auxiliary Instant
√
√
√
1, 2, 3
35
Local Instant
Police (Day
Zone)
Local alarm in levels 1 and 2. Report to CS in level 3. Police
Instant
√
√
√
(level 3
only)
1, 2, 3
38
Auxiliary
Water sensor ‡
Auxiliary Instant
√
√
√
1, 2, 3
Note:
Check marks (
√
) represent characteristics present in a group.
*
This group is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only
.
† Sounds instant police siren if two or more sensors are tripped within 4 minutes. Otherwise sensors are followers to delayed
sensors. If Alarm Verification is on, group 18 functions like group 17.
‡ This group has not been investigated by UL.
§ This group is required for UL-listed residential fire alarm applications.
Table B1: Sensor Group Characteristics (Continued)
No.
Name
Application
Alarm
Delay
Re
stor
al
Supervisory
CS R
eport
Ch
ime (Lev
el
1
)
Ac
tive
L
eve
ls
D i n i n g
R o o m
H a l l
B e d r o o m
B e d r o o m
B e d r o o m
P a t h o f P e r s o n W a l k i n g
M o t i o n S e n s o r
D e t e c t i o n P a t h / K i t c h e n M o t i o n S e n s o r
D e t e c t i o n P a t h / L i v i n g R o o m M o t i o n S e n s o r
K i t c h e n
L i v i n g
R o o m
WWW.DIYALARMFORUM.COM