Concord 4 Series Systems
26
Clear Memory (System Programming)
Clearing memory deletes all existing programming information (except the Dealer Code).
Note
Clearing the memory will
erase onboard hardwire
zone factory programming.
To Clear Panel Memory:
1. With the system in program mode, press A or B until the display shows
CLEAR MEMORY
.
2. Press # and the display shows
ENTER CODE TO CLEAR MEMORY
.
3. Enter the 4-digit installer or dealer code (if programmed)
+
#. After about five seconds, the
system restarts and the panel scans the bus to learn all bus devices.
If the system doesn’t respond as described, repeat step 3.
Programming Tier 2 Menu Items
This section guides you through programming tier 2 menu items as they appear in sequence. Fig-
ure 27 shows the menus available on tier 2.
Each menu on tier 2 represents a group of settings related to the menu name. Some tier 2 menus
break down into settings that affect the whole system (global) or a specific partition.
Using Shortcut Numbers
To go directly to a setting in tier 2, you can enter the shortcut number for that setting. Shortcut
numbers in this manual appear in parenthesis ( ), next to the setting name. For example, this
heading shows the Downloader Code global shortcut to be 0000.
Menus with partition settings have the series of shortcut numbers in parenthesis. For example,
this heading shows the Account Number partition shortcut number series to be 0010 - 0060.
The bold digit identifies the partition. To go directly to partition 3 account number, you would
enter 0030.
Shortcut numbers can be used from any setting location within tier 2.
To advance to tier 2 program menus:
With the system in program mode and the display showing
SYSTEM PROGRAMMING
, press #
once. The display should show
SECURITY
.
Security Menu
The
SECURITY
menu lets you choose whether security settings affect the whole system (global)
or a specific partition.
To access global or partition security menu items:
1. With the display showing
SECURITY
, press #. The display should show
GLOBAL
.
2. Press # again to advance to global settings, or press A or B to display
PARTITION n
, then press
# to advance to selected partition 1-6 settings.
The following describes how to program the Security settings that appear under
GLOBAL
.
Downloader Code
(0000)
Security-Global (Default = 12345)
Account Number
(00
1
0 - 00
6
0)
Security-Partition 1-6 (Default = 00000)
Downloader Code (0000)
Security-Global (Default = 12345)
The 5-digit downloader code is used in conjunction with downloader pro-
gramming. The downloader operator must have the panel account number
and downloader code in order to perform any programming.
Note
The Downloader Code cannot be deleted from panel memory. To change the
Downloader Code to its default setting, enter 12345 in the procedure to the right.
The Downloader Code will be reset to defaults during a Memory Clear only if the
Dealer Code is not set OR if the Dealer Code is used to initiate the Memory Clear.
Note
Downloader programming has not been investigated by UL.
To program a Downloader Code:
1. With the display showing
DOWNLOADER
CODE nnnnn
(current code)
, enter the desired
5-digit code, +
#. The display flashes the
entered code.
2. Press # and the display shows the new code.
WWW.DIYALARMFORUM.COM