Concord 4 Series Systems
48
Closing Reports
(06
1
01 - 06
6
01)
Reporting-Partition 1-6 (Default = off)
When this setting is on, the panel sends a closing report to the central
station after arming the system.
Note
To use this feature, the Open/Close Reports settings under the
PHONES
menu must be turned on for the specific CS Phone or Pager number.
To turn Closing Reports off or on:
1. With the display showing
CLOSING REPORTS
OFF/ON
(current setting)
, press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press # and the display shows the new setting.
No Activity
(06
1
02 - 06
6
02)
Reporting-Partition 1-6 (Default = off)
When this setting is on, the panel sends a no activity report to the cen-
tral station when the activity timeout expires (see
TIMERS—ACTIVITY
TIMEOUT
).
To turn No Activity reports off or on:
1. With the display showing
NO ACTIVITY OFF/ON
(current setting)
, press 1 (off) or 2 (on). The dis-
play flashes the entered setting.
2. Press # and the display shows the new setting.
Duress Option
(06
1
03 - 06
6
03)
Reporting-Partition 1-6 (Default = off)
(Default = off) When this setting is on, the system can be controlled
using a programmed duress code (see
SECURITY—PARTITION N—
DURESS CODE
) and will send a duress alarm to the monitoring station.
Note
For UL Listed installations, Duress Option must be set to off.
Do not use a duress code unless it is absolutely necessary. Using duress
codes often results in false alarms due to code entry errors. If a duress
code
is
absolutely necessary, use it with the audio verification module
to reduce false alarms and accidental dispatches.
To turn Duress Option off or on:
1. With the display showing
DURESS OFF/ON
(cur-
rent setting)
, press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
Force Armed
(06
1
04 - 06
6
04)
Reporting-Partition 1-6 (Default = off)
When this setting is on, the panel reports to the central monitoring station when a
user “force arms” the system.
Note
Forced arming occurs if the user presses BYPASS when arming the system with open
sensors/zones protesting.
Auto-forced arming occurs when the user does not press BYPASS when arming the sys-
tem with open sensors/zones protesting, then leaves through an entry/exit door and the
arming protest period expires. This causes the system to automatically bypass the open
(protesting) sensors.
Auto-forced arming always reports to the central monitoring station.
Auto-forced arming has not been investigated by UL.
To turn Force Armed off or on:
1. With the display showing
FORCE
ARMED OFF/ON
(current setting)
,
press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the
new setting.