Concord 4 Series Systems
54
Audio Verification Menu
The
AUDIO VERIFICATION
menu lets you set up the audio verification module (AVM) operation
in partition 1. If you want audio verification for partitions 2-6, you must install a “stand-alone”
audio verification module and a 4-Relay Output Module (HOM) (60-770) output for that parti-
tion.
The following describes the Audio Verification settings that appear under
PARTITION 1
.
Audio Verify
(09000)
Audio Verification-Partition 1 (Default = off)
This setting determines whether or not the
system can be accessed by phone for alarm
verification.
To turn Audio Verification off or on:
1. With the display showing
AUDIO VERIFICATION
, press #. The display shows
PARTITION 1
.
2. Press # again and the display shows
AUDIO VERIFY OFF/ON
(current setting)
.
3. Press 1 (off) or 2 (on). The display flashes the entered setting. Press # and the
display shows the new setting.
Audio Mode
(09001)
Audio Verification-Partition 1 (Default = 1)
This setting determines how the audio verification module operates. Choose
one of the following:
•
(1) Instant
—Allows the central station operator instant access for an
audio session by entering the AVM code or by pressing * (if an AVM
access code is not programmed) upon completion of panel alarm report
(also see
ACCESS TIMEOUT
). The panel does not report any alarms dur-
ing the AVM session except for fire alarms, even if the operator extends
the session by pressing any valid key.
•
(2) Callback
—Allows the central station operator to place a call to the
premises within 5 minutes of the alarm report (panel picks up after one
ring). The operator must press * or enter the AVM access code within 20
seconds after ring. The panel does not report any alarms during the AVM
session except for fire alarms, even if the operator extends the session by
pressing any valid key.
•
(3) Callback Silent
—Same as Callback, except premises phones do not
ring.
To set Audio Mode:
1. With the display showing
AUDIO VERIFY
OFF/ON
, press A or B until the display
shows
AUDIO MODE nn
(current setting).
2. Enter the desired mode number (1–3). The
display flashes the entered setting. Press
#
and the display shows the new setting.
Fire Shutdown
(09002)
Audio Verification-Partition 1 (Default = off)
This setting determines whether system sirens turn
off during a fire alarm audio session.
To turn Fire Shutdown off or on:
1. With the display showing
AUDIO VERIFY OFF/ON
, press A or B until
the display shows
FIRE SHUTDOWN OFF/ON
(current setting)
.
2. Press 1 (off) or 2 (on). The display flashes the entered setting. Press
# and the display shows the new setting.
Silent Talkback
(09003)
Audio Verification-Partition 1 (Default = off)
This setting determines whether the central station
operator can speak to persons on the premises (on)
or only listen (off) during a silent or duress alarm
audio session.
To turn Silent Talkback off or on:
1. With the display showing
AUDIO VERIFY OFF/ON
, press A or B until
the display shows
SILENT TALKBACK OFF/ON
(current setting)
.
2. Press 1 (off) or 2 (on). The display flashes the entered setting. Press #
and the display shows the new setting.
WWW.DIYALARMFORUM.COM