Concord 4 Series Systems
50
Siren Options Menu
The
SIREN OPTIONS
menu lets you set up siren operation and supervision.
The following describes how to program the settings that appear under
GLOBAL.
System Tamper
(06
1
09 - 06
6
09)
Reporting-Partition 1-6 (Default = off)
This setting determines how the panel handles possible tamper situations. When
this feature is on, the panel reacts as follows:
•
Initiates an alarm when the system prompts for an access code (arming/dis-
arming, etc.) and several wrong access codes are entered (40 consecutive
invalid keypresses).
•
Reports to the central station if a bus device stops communicating with the
panel.
•
Reports to the central monitoring station if a tamper condition occurs on
unarmed RF (wireless) devices.
Note
For UL Commercial Listed installations (UL 1610), System Tamper must be set to on.
To change the System Tamper set-
ting:
1. With the display showing
SYSTEM
TAMPER OFF/ON
(current setting)
,
press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new
setting.
Report Confirm
(06
1
11 - 06
6
11)
Reporting-Partition 1-6 (Default = off)
When this setting is on, system status speakers announce “Report is okay” fol-
lowed by a single beep each time a successful report is made to the central moni-
toring station. When turned off, no status message or beep sounds.
To change the Report Confirm setting:
1. With the display showing
REPORT
CONFIRM OFF/ON
(current setting)
,
press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new
setting.
Immediate Beeps
(0700)
Siren Options-Global (Default = off)
This setting determines whether the panel activates trouble beeps as
soon as a wireless device supervisory condition is detected (on), or if
the panel waits 10 hours after the supervisory condition is detected to
activate trouble beeps (off). (Refer to
TIMERS
—
GLOBAL
—
SUPERVI
-
SORY
TIME
).
Note
For UL Listed installations, this feature must be on.
To turn Immediate Beeps off or on:
1. With the display showing
IMMEDIATE BEEPS
OFF/ON
(current setting)
, press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press # and the display shows the new setting.
Disable Trouble Beeps
(0701)
Siren Options-Global (Default = off)
When turned on, the panel does not initiate beeps to alert users of non-
fire wireless device supervisory trouble and does not protest on arm-
ing if the condition exists.
Note
If Immediate Beeps is set to on, trouble beeps sound for supervisory trou-
ble conditions regardless of this menu setting.
Note
For UL Listed installations, Disable Trouble Beeps must be set to off.
To turn Disable Trouble Beeps off or on:
1. With the display showing
DISABLE TR BEEPS
OFF/ON
(current setting)
, press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press # and the display shows the new setting.
WWW.DIYALARMFORUM.COM