Concord 4 Series Systems
39
Timers Menu
The
TIMERS
menu lets you set up the various system feature times that affect the whole system
(global) or a specific partition.
The following describes how to program the Timers settings that appear under
GLOBAL
.
Phone Panic
(02
1
5 - 02
6
5)
Phone Options-Partition 1-6 (Default = off)
This setting determines whether or not a police panic alarm
can be activated from a touch-tone phone. When this feature is
on, pressing #
+
****** from a touch-tone phone on the pre-
mises causes a panic alarm.
To turn Phone Panic off or on:
1. With the desired partition selected, press A or B until the
display shows
PHONE PANIC OFF/ON
(current setting)
.
2. Press 1 (off) or 2 (on). The display flashes the entered
setting. Press # and the display shows the new setting.
Phone Access Key
(02
1
6 - 02
6
6)
Phone Options-Partition 1-6 (Default = #)
This setting determines which touch-tone phone button is used for system
access and control.
If the Local Phone Control feature is enabled, the user can pick up the phone
and press # (within 5 seconds) to access the security system. The panel seizes
the phone line and waits for the user to enter system commands. Phone access
can be changed from # to * (see the following note).
Note
Use the default setting (#) to avoid conflicts between the security system and other
phone devices and services. Many phone devices (such as answering machines,
computer modems, and FAX machines) and services (such as call-waiting, call-for-
warding, and some banking transactions) require * to initiate their operation, so using
* for this security feature could cause conflicts.
To change the Phone Access Key:
1. With the desired partition selected, press
A or B until the display shows
PHONE
ACCESS KEY #/*
(current setting)
.
2. Press 1 (for *) or 2 (for #). The display
flashes the entered setting. Press # and
the display shows the new setting.
Supervisory Time
(0300)
Timers-Global (Default = set randomly
between 01:00 and 04:00)
This setting determines what time of day the panel sends supervisory,
low battery, or auto phone test reports to the central station.
Note
The panel clock must be set with the correct time for accurate supervisory
time reporting. See “Time and Date Menu”.
To set the Supervisory Time:
1. With the display showing
SUPERVISORY TIME
HH:MM
(current setting)
, enter the desired 4-
digit time value. For example, enter 0330 to
set the supervisory time for 3:30
A
.
M
. The dis-
play flashes the entered setting.
2. Press # and the display shows the new setting.
RF Tx Timeout
(0302)
Timers-Global (Default = 12 hours)
This setting determines how many hours (2–24) the panel has to receive at least
one signal from a wireless sensor (learned into a supervised group). If the panel
does not receive a signal from any supervised wireless sensor within the set time,
the panel reports a supervisory condition to the central station.
Note
For UL 985, 1610 & 1635 listed installations, the RF Tx Timeout must be set to 4
hours. For UL 1023 listed installations, the RF Tx Timeout must be set to 24 hours.
To set the RF Tx Timeout:
1. With the display showing
RF TX TIME-
OUT nn HOURS
(current setting)
, enter
the desired timeout value (2–24). The
display flashes the entered setting.
2. Press # and the display shows the new
setting.
WWW.DIYALARMFORUM.COM