![GE Digital Energy L60 Скачать руководство пользователя страница 560](http://html.mh-extra.com/html/ge-digital-energy/l60/l60_instruction-manual_571854560.webp)
10-4
L60 LINE PHASE COMPARISON SYSTEM – INSTRUCTION MANUAL
UPGRADE FIRMWARE
CHAPTER 10: MAINTENANCE
10
4.
If the device has the CyberSentry option, use the User Name of "Administrator" or "Engineer", and the password
programmed for the selected role. The default password is "ChangeMe1#" (without quotation marks).
5.
If the device does not have the CyberSentry option, use the User Name of "Setting", and the password programmed for
the Setting role. The default password is "ChangeMe1#" (without quotation marks).
6.
Upload the backup file copy with the CID extension. WinSCP uses drag-and-drop or copy-and-paste for this.
7.
Manually copy the remaining settings, outlined as follows.
To manually copy remaining settings:
1.
Settings listed in section 4.1.2 Settings Files are not transferred to the UR device with settings files. Enter them
manually either via the front panel or via EnerVista UR Setup software. The values that these settings had at the time
the backup was created are contained within the backup file, accessed through EnerVista UR Setup software.
10.3 Upgrade firmware
The firmware of the L60 device can be upgraded, locally or remotely, using the EnerVista software. Instructions are
outlined here and in the Help file under the topic “Upgrading Firmware.”
Upgrades are possible for the same release (such as 7.01 to 7.02) and from one firmware version to another (such as 7.2 to
7.3). When upgrading to another firmware version, check the release notes for compatibility. Release notes are located in
the Support Documents section of the website at
http://gedigitalenergy.com/app/ViewFiles.aspx?prod=urfamily&type=9
If you are upgrading from version 7.0 or 7.1 to 7.2 or later, some CPU modules require a new boot version. Update this first.
To upgrade the firmware:
1.
If required, download the boot file and/or firmware from
http://www.gedigitalenergy.com/app/ViewFiles.aspx?prod=urfamily&type=7
The firmware and boot files are .bin files.
2.
Navigate to
Settings > Product Setup > Security
and ensure that the
Remote Setting Authorized
and
Local Setting
Authorized
settings are "ON." On the front panel of the device, the path is
Settings
Product Setup
Security
Dual
Permission Security Access
.
If using CyberSentry security, also ensure that the relay and firmware are not locked under the
Settings > Product
Setup > Security > Supervisory
settings.
3.
In EnerVista, back up the device settings by right-clicking the device and selecting
Read Device Settings
. In the
window that displays, select an existing file to overwrite, or enter a name for a new settings file and optionally a
location for the new file. Click the
Receive
button to start the backup.
If an "Incompatible device order codes or versions" message displays, it means that you are trying to overwrite a file
for another product. You access the
Convert Settings File
option by right-clicking the file in the
Offline Window
area
at the lower left.
4.
In EnerVista, navigate to
Maintenance > Update Firmware
.
First select the boot file if applicable, locating the .bin file, and proceed. Restart the device, the EnerVista software, and
refresh the order code in EnerVista under the
Device Setup
button.
To update the firmware, click
Maintenance > Update Firmware
, select the firmware update by locating the .bin file,
and proceed with the update.
If an "Unable to put relay in flash mode" message displays, set the
Settings > Product Setup > Security > Dual
Permission Security Access > Remote Setting Authorized
and
Local Setting Authorized
settings to "ON" and try
again.
When the update is finished, restart the device by clicking
Maintenance > Reboot Relay Command
, restart the
EnerVista software, and refresh the order code in EnerVista under the
Device Setup
button. As the device is starting
up, verify the boot and firmware version, or in EnerVista check them under
Actual Values > Product Info > Firmware
Revisions
. The boot version is not the same as the firmware revision, and the firmware revision reflects the UR release,
for example firmware revision 7.3 is UR release 7.3.
Содержание L60
Страница 130: ...4 30 L60 LINE PHASE COMPARISON SYSTEM INSTRUCTION MANUAL LOGIC DIAGRAMS CHAPTER 4 INTERFACES 4 ...
Страница 464: ...5 334 L60 LINE PHASE COMPARISON SYSTEM INSTRUCTION MANUAL TESTING CHAPTER 5 SETTINGS 5 ...
Страница 498: ...7 10 L60 LINE PHASE COMPARISON SYSTEM INSTRUCTION MANUAL TARGETS MENU CHAPTER 7 COMMANDS AND TARGETS 7 ...
Страница 570: ...10 14 L60 LINE PHASE COMPARISON SYSTEM INSTRUCTION MANUAL DISPOSAL CHAPTER 10 MAINTENANCE 10 ...
Страница 582: ...A 12 L60 LINE PHASE COMPARISON SYSTEM INSTRUCTION MANUAL FLEXANALOG ITEMS APPENDIX A FLEXANALOG OPERANDS A ...
Страница 588: ...C 4 L60 LINE PHASE COMPARISON SYSTEM INSTRUCTION MANUAL REVISION HISTORY APPENDIX C MISCELLANEOUS C ...
Страница 592: ...iv L60 LINE PHASE COMPARISON SYSTEM INSTRUCTION MANUAL ABBREVIATIONS ...