635/600-SERIES HARDWARE INSTALL GUIDE
Chapter-Page
1-4
1.3
Hardware Certifications & Compliances
The 600-Series & 635-Series Access Control Panel (ACP) is listed as follows:
REGULATORY STANDARDS
UL 294, Fifth Edition, Access Control System Units
UL 1076, Fifth Edition, Proprietary Burglar Alarm Units and Systems
CSA C22.2, No. 205-M1983, First Edition, Signal Equipment
CE EN-50133
RoHS Compliant
Installation and Service for Galaxy Hardware:
Installation and service of Galaxy hardware / components must be performed by a
Galaxy-certified
Technician
.
Power Source for Galaxy Access Control Panel (ACP):
The
Galaxy Controller requires a continuous power source from a 110VAC
non-switched outlet
that is less than
25 feet from the control panel. (Do not connect the power adapter to an outlet that is controlled by a switch.)
AC Power Transformer, Class-2, Plug-in Type
(shown with Altronix Power Supply)
:
The AC Power Transformer, used by Galaxy controllers, must meet following requirements:
•
Must be a Class-2 Plug-in Transformer with fused secondary.
•
AC Transformer must be plugged into the 110VAC non-switched, duplex outlet.
•
Transformer must not be shared by any other equipment.
•
Requires 1 pair of 18 AWG wire (minimum).
•
Input-rated at 120 VAC / 48 VA at 60 Hz,
•
Output-rated 16.5 VAC / 40VA at 60 Hz.
•
Must be UL-Listed and CSA-Certified.
Galaxy access control panels that require AC transformers are only intended for use with a UL Listed, Class-2
transformers, like the one manufactured by
Universal Power Group No. UB1640WR
.
- - - See NEXT PAGE for LifeSafety Power Supply - - -
12VDC / 8Ah Battery