8.
From the
Panel Status screen
, click on the
Panel Configuration link
(at the bottom of the screen) to open the
Panel Configuration
screen.
•
UPDATE button –
sends (posts) your changes to the panel (CPU).
•
CANCEL button –
clears changes to fields before update; Cancel will not undue changes you already updated.
Figure 47 – Example of ‘Panel Configuration’ screen – ( CPU PROGRAMMING )
This screen allows the technician to change the Panel’s current configuration and connection parameters to the
Event Server.
NOTES
•
The panel
Cluster ID
and
Unit ID
must match the ID’s in the System Galaxy database. The Unit ID must be unique within the
cluster. CPU Number should be 1.
•
Encryption Phrase
(if used) must match the phrase programmed at the Event Server. All panels on the same Event Server
must match.
•
Event Server IP address
Typically you will configure one Event Server IP address. Port 3001 is the default port and must be
unblocked. Additional Event Servers provide redundancy in case the first event server is turned off. The panel will switch to the
next available server. (if used with encryption, all servers’ encryption phrases must match)
•
The Event Server IP Address
must