635-SERIES HARDWARE M ANUAL
Chapter-Page
2-10
1.4 Board Compatibility and Capability (635 vs. 600 models)
The table below shows the compatibility of Galaxy boards and features when using SG 10.X software.
NOTES ABOUT REPAIR / MAINTENANCE / UPGRADE OF 600-MODEL CONTROLLERS
BOARDS ARE SWAPPABLE! You can replace old 600-model CPU, DPI, OR DSI with a new 635-model board and
maintain existing functionality in your hardware and software configuration.
1.
If you are just swapping the boards, you should NOT need to change any software configuration.
a)
KEEP THE SAME BOARD ID:
BEFORE you install the 635 Board, you must set the 635-model board to have the same
Board ID (dipswitch setting) as the old 600-model board. This way the new board will seamlessly replace the existing
board and prevents confusion/problems on the system.
b)
KEEP THE SAME IP ADDRESS
and Network Settings (CPU).
the new CPU will seamlessly replace the existing CPU.
2.
635 and 600 boards can interoperate within the same panel, and same Cluster/Loop. However, when you are upgrading
peripheral hardware or readers, you need to be aware of limitations the older 600 hardware inherently has.
Table 14: BOARD COMPATIBILITY CHART for SG10
635-SERIES CONTROLLER
600-SERIES CONTROLLER
635 CPU Board
-
Processor
600 CPU Board
–
Processor
•
Operates in same loop /system with other 600 Panels (CPUs)
•
Supports all 635 & 600 daughter boards
•
Supports all 635-series
RS485
Modules
•
Supports all 600-series
RS485
Modules – restrictions apply
*
•
Supports Destination-driven elevator systems
•
Supports Card Tour Board
•
Operates in same loop /system with 635 Panels (CPUs )
•
Compatible/Supports all 600 daughter boards
•
Supports 635 DRM (Reader board)
•
Supports 600 Output/Elevator Modules on 600 DSI
•
Destination-driven elevators and Card Tour are not supported
.
635-MODEL BOARDS
Requires 635-CPU*
600-MODEL BOARDS
600 Daughter Boards
635 Daughter Boards
600 DIO Board
600 DIO Board
600 DIO Board
600 DIO Board
635 DRM Reader
Board
600 DPI Reader Board
635 DRM Reader
Board
600 DPI Reader Board
635 DSI Serial Board
600 DSI Serial
Board
635 DSI Serial Board
600 DSI Serial
Board
•
600 Output Module (general
output or elevator control)
•
LCD Clock unit
•
Schlage PIM 485 ODT (legacy)
•
600 Output Module (general
output or elevator control)
•
LCD Clock unit
•
Schlage PIM 485 ODT (legacy)
•
600 Output Module (general
output or elevator control)
•
LCD Clock unit
•
Schlage PIM 485 ODT (legacy)
•
600 Output Module (general
output or elevator control)
•
LCD Clock unit
•
Schlage PIM 485 ODT (legacy)
•
Assa Abloy Aperio (SG 10.1)
•
Assa Abloy Aperio (SG 10.1)
Assa Not supported on 600-CPU
Assa Not supported on 600-CPU
•
Salto Salis Wireless (SG 10.2)
•
Salto Salis Wireless (SG 10.2)
Salto Not supported on 600-CPU
Salto Not supported on 600-CPU
•
Schlage AD-300 (SG 10.2)
•
Schlage AD-400 Wifi (10.2)
•
Mixed AD-300/AD-400 (10.2)
•
Schlage AD-300 (SG 10.2)
•
Schlage AD-400 Wifi (10.2)
•
Mixed AD-300/AD-400 (10.2)
Schlage AD-series not supported
on 600-CPU
(NOTE IN THIS SCENARIO, a 635-DSI
IS LIMITED BY THE 600-CPU)
Schlage AD-series not supported on
600-CPU
(NOTE IN THIS SCENARIO, a 635-DSI IS
LIMITED BY THE 600-CPU
)
•
Assa IP Readers (SG 10.4)
•
Assa IP Readers (SG 10.4)
ASSA IP not supported 600-CPU
ASSA IP not supported 600-CPU
•
635 Input Module (SG 10.4)
<< Not supported on 600-DSI
•
635 Remote Door DRM (10.4)
<< Not supported on 600-DSI
COMPATIBLE MODULES (RS-485 multi-drop)
COMPATIBLE MODULES (RS-485 multi-drop)
635 Output (or Elevator) Relay Module (using 635 DSI )
600-Model Relay Board using either DSI on 600-CPU
635 Door Module (using 635 CPU & 635 DSI, SG 10.3)
<< 635 Door Module not supported on 600 CPU
635 Input Module (using 635 CPU & 635 DSI, SG 10.4)
<< 635 Input Module not supported on 600 CPU