600-SERIES HARDWARE MANUAL
Appendix Q - 635 DPI Installation
APPENDIX-Page
Q-4
Q.2
QUICK STEPS for installing a 635 DPI
This addendum assumes you are properly following the requirements and install instructions for the
controller cabinet, CPU, daughter boards, etc., as described in the Chapter 2 of the 600 Hardware Guide.
CAUTION!
Do NOT interrupt power while a DPI is in the flashing process
. Interrupting power during a
flash update can damage the memory. Factory restoration is required to recover the board operation.
CAUTION! Do NOT connect a 5volt reader directly to the 635 DPI; 12volt readers are supported as is.
IMPORTANT! Use a separate power supply for Locks. Install surge protection diodes at the lock end.
635 DPI QUICK STEP TABLE
(detailed instructions for each step are found on the following pages)
635 DPI - BOARD PREP
1.
Verify / Flash CPU
(from SG software/Loader)
Use System Galaxy software to verify CPU flash version.
Flash as needed - CPU 1 (and CPU2 if used) must use 4.60 flash (or higher)
.
2.
Obtain a valid DPI Board ID
Factory default =16 (1-16 supported). If replacing a board, reuse same ID as old
board. If installing new, keep factory default (16) if not already in use, otherwise ID
to a unique ID with the panel (
see the System Galaxy Controller Properties screen
)
3.
Set the Board ID
(dipswitch)
using the binary dipswitch
(
see diagram & Binary Address Table
)
4.
Reader Voltage NOTICE
IMPORTANT:
5V reader requires a voltage regulator to be installed.
5.
Install Supervision
Resistors
(optional)
Factory default = 4.7k
Ω
socketed swappable resistor;
EOL resistors must match value of socketed resistor.
6.
Set Relay-1 Jumpers
Standard Dry Relay operation =OUT; New Wet Relay operation = IN (
see diagram
)
635 DPI - BOARD INSTALL
7.
Install Board in card slot
Place mounting bracket under standoffs (
see diagram
Chap. 2 of 600 Hardware Guide
)
635 DPI - WIRING (wire, but do not connect 2-Piece connectors to the board yet)
8.
Wire Lock Relay 1
Follow diagrams carefully
for the type of install (wet or dry relay operation).
a. Wire reader, REX, contact
Land wires correctly / ground shielding (
see diagram in Chap. 2 section 11
)
b. Wire Relay 2 (if used)
Normally Open and Normally Closed devices are supported (
9.
Wire DPI power connector
Observe polarity; swap over to the 3-pin power plug.
CAUTION: SEE Diagrams in following sections for wiring lock power supply.
635 DPI - BRING BOARD ONLINE
(
also
see Chap. 2 for details on these steps
)
10.
Connect DPI power
Connect the DPI board power (
D12 LED
should light up solid)
11.
Connect data/ribbon
Connect the 635 DPI to the data ribbon cable. Allow all daughter boards to update
flash without power interruption.
Caution:
default
10-minute update delay
occurs; issuing a
CLEAR AUTO command will bypass the delay (board does not auto-flash if it matches the
CPU version). Always allow flashing to complete without interruption.
12.
DPI Flash/Load Data
Allow DPI to flash without power interrupt (Galaxy Config Tool / HyperTerm / Web).
Use SG Controller Loader to load data if adding new doors
after
all flashing completes.
13.
Connect field devices
Connect each field device (support 12V readers; 12/24V Locks)
14.
Load data to the panel
Configure field devices into the software. Use SG Loader to load panel.
15.
Walk-Test your devices
Test the field devices to ensure operation. (
see diagram in Chap. 2
)