635/600-SERIES HARDWARE INSTALL GUIDE
Chapter-Page
1-20
Table 6: BOARD COMPATIBILITY CHART for SG 10/11
(
Tables 7 & 8 for SG-9 or lower
)
WHEN IS UPGRADING SG SOFTWARE REQUIRED ?…
if an
SG version
is noted, then that is the minimum version of SG required to support that board/feature
if the
no version
is listed, then any version of SG 10 supports the feature.
WHEN IS UPGRADING HARDWARE REQUIRED ?…
Installing Wireless Readers, IP Readers – you must upgrade to 635 CPU and 635-DSI
Installing 635-Input Module – you must upgrade to 635 CPU and 635-DSI
Installing a Galaxy 485 Remote Door Module – You must upgrade to 635-CPU, 635-DRM, and 635-DSI.
Installing newer destination-driven elevator systems, then you must install all 635-model hardware.
•
600-model boards can interoperate with 635-model boards in the same system and within the same control panel
.
•
You can replace older 600-model boards with new 635-model boards as needed.
•
The older 600-model boards do not support the newer hardware interfaces and features supported by the 635.
635-SERIES CONTROLLER
600-SERIES CONTROLLER
635 CPU Board
-
Processor
600 CPU Board
–
Processor
•
Operates in same loop /system with 600 CPUs
•
Supports all 635 & 600 daughter boards
•
Supports all 635-series
RS485
Modules
•
Supports all 600-series
RS485
Modules – restrictions apply
*
•
Supports Destination-driven elevator systems
•
Supports Card Tour Board
•
Operates in same loop /system with 635 CPUs
•
Compatible/Supports all 600 daughter boards
•
Supports 635 DRM (Reader board)
•
Supports 600 Output/Elevator Modules on 600 DSI
•
Destination-driven elevator systems and Card Tour are not supported.
635 DAUGHTER BOARDS
600 DAUGHTER BOARDS
635 DAUGHTER BOARDS
600 DAUGHTER BOARDS
600 DIO Board
600 DIO Board
635 DRM Reader
Board
600 DPI Reader Board
635 DRM Reader
Board
600 DPI Reader Board
635 DSI Serial Board
600 DSI Serial
Board
635 DSI Serial Board
600 DSI Serial
Board
•
600 Output Module (general
output or elevator control)
•
LCD Clock unit
•
Schlage PIM 485 ODT (legacy)
•
600 Output Module (general
output or elevator control)
•
LCD Clock unit
•
Schlage PIM 485 ODT (legacy)
•
600 Output Module (general
output or elevator control)
•
LCD Clock unit
•
Schlage PIM 485 ODT (legacy)
•
600 Output Module (general
output or elevator control)
•
LCD Clock unit
•
Schlage PIM 485 ODT (legacy)
•
Assa Abloy Aperio (SG 10.1)
•
Assa Abloy Aperio (SG 10.1)
<< Not supported on 600-CPU
<< Not supported on 600-CPU
•
Salto Salis Wireless (SG 10.2)
•
Salto Salis Wireless (SG 10.2)
<< Not supported on 600-CPU
<< Not supported on 600-CPU
•
Schlage AD-300 (SG 10.2)
•
Schlage AD-400 Wifi (10.2)
•
or Mix AD-300/AD-400 (10.2)
•
Schlage AD-300 (SG 10.2)
•
Schlage AD-400 Wifi (10.2)
•
or Mixed AD-300/AD-400 (10.2)
•
Assa IP Readers (SG 10.4)
•
Assa IP Readers (SG 10.4)
•
635 Input Module (SG 10.4)
<< Not supported on 600-DSI
•
635 Remote Door DRM (10.4)
<< Not supported on 600-DSI
COMPATIBLE MODULES (RS-485 multi-drop)
COMPATIBLE MODULES (RS-485 multi-drop)
600 Elevator/Output Module
( using DSI )
600 Elevator/Output Module
( using DSI )
635 Door Module (using 635 CPU & DSI, SG 10.3)
<< 635 Door Module not supported on 600 CPU
635 Input Module (using 635 CPU & DSI, SG 10.4)
<< 635 Input Module not supported on 600 CPU