5.3 Cabling the ETERNUS CS800 S6 System
3. Connect the LAN ports and optionally the iRMC port to the appropriate networks. At
least one of the LAN ports must be connected.
4. If your ETERNUS CS800 also provides FC ports: Connect them to the SAN or directly to
the appropriate devices.
5.3.3
Scale System
There are three different versions of the Scale model, which can be distinguished by the
ports respectively the PCI slots used in the server, see table
Optionally up to ten ETERNUS DX100 S3 drive enclosures can be connected to the DX100
controller enclosure to provide a disk capacity of more than 32TB (up to 352TB).
Internal cabling of the Scale system
The Scale model requires connecting the ETERNSU DX100 S3 storage subsystem to the
server using LAN and FC cables. In addition the optionally available drive enclosures must
be connected to the controller enclosure using SAS cables.
The required cables for this internal cabling are delivered together with the system.
Proceed as follows to prepare the internal cabling:
1. Connect the MNT LAN ports of both DX100 controller modules to the server:
Figure 68: LAN connection between server and DX100 controller enclosure
a. CM#0 MNT port has to be connected to the left onboard LAN port (LAN1 at LoM).
b. CM#1 MNT port has to be connected to the uppermost LAN port of the PCI card in
slot 7.
ETERNUS CS800
94
Содержание ETERNUS CS800 S6
Страница 1: ...English ETERNUS CS800 S6 User Guide V3 2 7 Edition April 2017 ...
Страница 131: ...7 3 The Remote Management Console Figure 98 Remote Management Pages Map ETERNUS CS800 131 ...
Страница 173: ...8 8 AIS Connect Figure 132 AISConnect Wizard Confirm ETERNUS CS800 173 ...
Страница 449: ...16 2 Storage Subsystem Figure 313 Inserting the 3 5 inch HDD module ETERNUS CS800 449 ...