5.2 Installing the components in the rack
Mounting the rail systems
Figure 53: Fit the Left Support System in the PRIMECENTER Rack
CAUTION!
When using telescopic rails, the rack must be protected against tilting.
1. Identify the right and the left rail (see label or imprint on the rail).
2. Position the rail on the rear left support bracket by inserting the retaining bolts (1).
3. Press the rail together (2).
4. Move the rail outwards until the designated position (grid of support upright) is
reached (3).
The black bolts must lock in the corresponding holes.
5. Press the bracket backwards until the rail engages (4).
CAUTION!
l
The toothed levers must be closed.
l
The two black bolts must be flush with the bracket.
ETERNUS CS800
82
Содержание ETERNUS CS800 S6
Страница 1: ...English ETERNUS CS800 S6 User Guide V3 2 7 Edition April 2017 ...
Страница 131: ...7 3 The Remote Management Console Figure 98 Remote Management Pages Map ETERNUS CS800 131 ...
Страница 173: ...8 8 AIS Connect Figure 132 AISConnect Wizard Confirm ETERNUS CS800 173 ...
Страница 449: ...16 2 Storage Subsystem Figure 313 Inserting the 3 5 inch HDD module ETERNUS CS800 449 ...