3.2 Storage Modules
LED name
LED status
Description
Identify
blinks blue
The installation location of the I/O module is
identified according to the instruction that is issued
from ETERNUS Web GUI or ETERNUS CLI.
Fault
amber
The I/O module is in error status.
Table 15: Status and meanings of each LED (I/O module of the ETERNUS DX100 S3 drive
enclosure)
Power Supply Unit (PSU)
The power supply unit transforms input AC power from a power socket to DC power and
supplies power to each component. Each power supply unit contains fans.
Figure 44: Power supply unit (PSU) of the ETERNUS DX100 S3 drive enclosure
LED name
LED status
Description
Power
green
AC power is supplied to the power supply
unit.
Fault
amber
AC power is not supplied to the power
supply unit.
AC missing
amber
AC power is not supplied to this power supply unit,
but AC power is supplied to the other power supply
unit.
Fan fail
amber
The power supply unit or the fan in the power supply
unit is in error status.
Table 16: Status and meanings of each LED (power supply unit)
ETERNUS CS800
68
Содержание ETERNUS CS800 S6
Страница 1: ...English ETERNUS CS800 S6 User Guide V3 2 7 Edition April 2017 ...
Страница 131: ...7 3 The Remote Management Console Figure 98 Remote Management Pages Map ETERNUS CS800 131 ...
Страница 173: ...8 8 AIS Connect Figure 132 AISConnect Wizard Confirm ETERNUS CS800 173 ...
Страница 449: ...16 2 Storage Subsystem Figure 313 Inserting the 3 5 inch HDD module ETERNUS CS800 449 ...