6.3 Running the Getting Started Wizard
Primary, Secondary, and Tertiary
DNS IP Address
(Optional) The IP addresses of up to three DNS servers
used to resolve domain names and translate them into
IP addresses.
You must specify a DNS IP address if you plan
to use hostname format when configuring an
NTP time server, outgoing e-mail server,
replication sources and targets, and other
information.
The
DNS Suffix Search List
and
DNS IP Addresses
cannot be modified if the
ETERNUS CS800 is currently joined to a Windows domain. To disjoin a Windows
domain, see
"Disjoining a Workgroup or Domain" on page 197
Configuring Bonding Details
Under
IP Address Configuration > Bonding Details
, configure bonded devices (see
"Network Page: Bonding Details" on page 109
):
Figure 82: Network Page: Bonding Details
1. If necessary, click the
Show
link to show the bonding details table.
2. For each available bonded device (
bond0
,
bond1
, and so on), select two or more
Ethernet ports with the same link speed to assign to the bond. Or select
Not Bonded
to leave a port unassigned to any bond.
If no ports are assigned to a bond, the bond cannot be configured. That is, settings
cannot be entered for the bond in the
Interface Details
or
IP Address
tables because
no Ethernet ports are assigned to the device.
All ports assigned to the same device are bonded together into a single logical port.
For example, if you select
bond0
for port
eth1
and port
eth2
, both ports are bonded
together in the
bond0
device. A bonded device can contain two or more ports.
All ports associated with a bond must have the same link speed (1GbE or 10GbE).
3. For each bonded device, specify the bonding mode:
ETERNUS CS800
109
Содержание ETERNUS CS800 S6
Страница 1: ...English ETERNUS CS800 S6 User Guide V3 2 7 Edition April 2017 ...
Страница 131: ...7 3 The Remote Management Console Figure 98 Remote Management Pages Map ETERNUS CS800 131 ...
Страница 173: ...8 8 AIS Connect Figure 132 AISConnect Wizard Confirm ETERNUS CS800 173 ...
Страница 449: ...16 2 Storage Subsystem Figure 313 Inserting the 3 5 inch HDD module ETERNUS CS800 449 ...