16.1 ETERNUS CS800 S6 Hardware
Figure 305: Installing the PSU
l
Insert the PSU module into its slot.
l
Push the PSU module into its slot (1) as far as it will go until the locking latch
snaps in place (2).
CAUTION!
Ensure that the PSU module properly engages in its slot and is locked in
position in order to prevent it from sliding out of the chassis during
transportation.
l
If applicable, fold down the handle on the PSU module (3).
Connecting the server to the mains
In its basic configuration level the server has a hot-plug power supply unit. A second
hotplug power supply unit can be added to ensure a redundant power supply. If one
power supply unit is defective, the other then guarantees unimpaired operation. Each
hot-plug power supply unit can be replaced during operation.
CAUTION!
The server is automatically set to a mains voltage in the range 100 V - 240 V.
You may only operate the server if its rated voltage range corresponds to the
local mains voltage.
l
Connect the power cord to the power supply unit.
l
Connect the mains plug to a grounded mains outlet in the in-house power supply
ETERNUS CS800
442