17.2 Storage Expansion - Scale
Figure 326: ETERNUS DX100 S3 cabling with one drive enclosure
Figure 327: ETERNUS DX100 S3 reverse cabling with two to ten drive enclosures
The following step by step instructions can be used to verify or to plug the cables:
a. The SAS port of
CE CM#0
must be connected to the
SAS IN port of DE-1 IOM#0
.
b. Only if there are more than just one DE:
The
IOM#0 SAS OUT port of DE-1
must be connected to the
IOM#0 SAS IN port of
DE-2
. If there are further DE’s they must be connected in the same way.