6.1 Switching on the System
6.1
Switching on the System
Proceed as follows:
1. (Scale model only): Turn on all PSU switches on the rear side of the storage modules.
a. Check that the LINE LEDs of all storage expansion modules are green.
b. Press the power switch on the left flange cover of the storage base module.
c. Wait until the READY LED of the storage base module glows green.
2. Press the power button of the server (see figure
"Base and server power button" on
).
3. Wait 15 minutes for the system to boot before continuing with the procedure.
Table 22: Base and server power button
Background Initialize
The storage modules are preconfigured in the factory and a Background Initialize process
has been started which runs autonomously on the storage system when it is switched on.
This Background Initialize continues to run on the customer side. Depending on the
configuration (number of storage modules), it can run for between one and several days.
This is NOT an error.
Since the
Background Initialize
runs autonomously on the storage system, the server can
consequently be rebooted and powered off without any restriction. If the storage base
module needs to be powered off, this can be done using the power switch on the front
panel.
As soon as the storage base is powered on again, the Background Initialize process is
automatically continued.
If an additional expansion module is integrated, a Background Initialize process is also
started here. The same rules apply as above.
ETERNUS CS800
100
Содержание ETERNUS CS800 S6
Страница 1: ...English ETERNUS CS800 S6 User Guide V3 2 7 Edition April 2017 ...
Страница 131: ...7 3 The Remote Management Console Figure 98 Remote Management Pages Map ETERNUS CS800 131 ...
Страница 173: ...8 8 AIS Connect Figure 132 AISConnect Wizard Confirm ETERNUS CS800 173 ...
Страница 449: ...16 2 Storage Subsystem Figure 313 Inserting the 3 5 inch HDD module ETERNUS CS800 449 ...