15.2 Common Problems and Solutions
15.2.4 Replication Problems
The table below describes corrective actions for problems occurring with the replication.
Priority Level
Description
The replication was paused,
but the replication is still in
process.
When you click
Pause
, the system will continue to
replicate the current tag or block of information in
process. The process of completing the current tag
replication can take up to 15 minutes to complete. Once
that tag has completed replication the system will pause
and wait to resume.
The replication was paused
and a
Failure
event was
generated in the
Replication
Events
page.
This is normal. When a replication is paused, a failure
event is generated on the
Replication Events
page. They
system will continue the replication when you click
Resume
.
Replication was disabled while
a replication was in process
and the replication completed.
If you click
Disable
during a replication in process, the
system will complete the entire replication and then
disable replication on the system. The system will be
unable to replicate until you click
Enable
.
Enabled replication on a NAS
share and received the
following Event:
No
destination host is
specified for
replication.
You must configure the target system prior to configuring
the source. If the target system is not configured first, you
will not be able to designate the replication target.
Able to enable and schedule
replication for NAS even
though no target IP
configured.
It is possible to enable and schedule a replication when a
target system has not been configured. The replication
will not start until a target system is configured.
Table 27: Replication Problems
15.2.5 Temperature Problems
Temperature problems are generally caused by incorrect room temperature, poor air
circulation inside the ETERNUS CS800 rack or components, or a malfunctioning cooling fan.
Use the following procedure if a temperature problem is reported:
1. Check the ambient temperature of the room containing the ETERNUS CS800 system to
verify that the temperature falls within the specified range.
2. Inspect for adequate air circulation inside the rack. Some racks may provide
additional fans to improve air circulations. Check the fan for proper operation. Clean
ETERNUS CS800
438
Содержание ETERNUS CS800 S6
Страница 1: ...English ETERNUS CS800 S6 User Guide V3 2 7 Edition April 2017 ...
Страница 131: ...7 3 The Remote Management Console Figure 98 Remote Management Pages Map ETERNUS CS800 131 ...
Страница 173: ...8 8 AIS Connect Figure 132 AISConnect Wizard Confirm ETERNUS CS800 173 ...
Страница 449: ...16 2 Storage Subsystem Figure 313 Inserting the 3 5 inch HDD module ETERNUS CS800 449 ...