Power Requirements
Voltage
AC 100 – 120 V / 200 – 240 V
Frequency
50 Hz / 60 Hz
Power Consumption
Min. 160 W, max. 6390 W
Power Phases
Dual
Table 34: Power Requirements
Climatic Environment
Temperature
15 °C to 35 °C (59 °F to 95 °F)
Relative Humidity
20 % to 80 % (non-condensing)
Heat Emission
Min. 580 kJ/h, max. 23 000 kJ/h (min. 520 BTU/h, max. 21
800 BTU/h)
Sound Pressure
49 – 53 dB(A)
Table 35: Environmental
Compliance with Standards
Product Safety
UL60950-1, CSA60950-1, EN60950-1, IEC60950-1, GOST
Electromagnetic
Compatibility
FCC Part-15 Class A, ICES-003 Class A, EN55022 Class A,
VCCI Class A, AS/NZS CISPR22 Class A, CNS13438(C6357)
Class A, C-Tick, BSMI
Electromagnetic Immunity
EN 55024
CE Certification
Electromagnetic Compatibility Directive 2004/108/EC, Low
Voltage Directive 2006/95/EC
Environmental Compliance
RoHS-compliant (Restriction of Hazardous Substances),
WEEEcompliant (Waste Electrical and Electronically
Equipment)
Compliance Notes
There is general compliance with the safety requirements
of all European countries and North America. National
approvals required in order to satisfy statutory
regulations or for other reasons can be applied for on
request.
Compliance Link
http://globalsp.ts.fujitsu.com/sites/certificates/default.aspx
Table 36: Compliance with Standards
ETERNUS CS800
463
Содержание ETERNUS CS800 S6
Страница 1: ...English ETERNUS CS800 S6 User Guide V3 2 7 Edition April 2017 ...
Страница 131: ...7 3 The Remote Management Console Figure 98 Remote Management Pages Map ETERNUS CS800 131 ...
Страница 173: ...8 8 AIS Connect Figure 132 AISConnect Wizard Confirm ETERNUS CS800 173 ...
Страница 449: ...16 2 Storage Subsystem Figure 313 Inserting the 3 5 inch HDD module ETERNUS CS800 449 ...