FSK-RAP816-V2015.04
8
PCB Layout
1. AC Input
The two wires from the transformer are connected to these
terminals and supply power the system.
2. Network Connections
The network terminals provide connections to the remote keypads
and zone expanders. The RED and BLK terminals provide power
whilst the GRN and YEL terminals are the data signals.
3. Zone Inputs 1 to 8
Detection devices such as movement sensors, vibration and door
contacts are connected to the zone input terminals. There are
several ways in which to wire a detection device (see page 10). Each
zone is fully programmable, see page 19 for information on
programming zones.
4. Aux Tamper Input
This terminal provides tamper detection for auxiliary devices. If it is
not required link it to 0V.
5. Auxiliary 12V
These terminals provide auxiliary power for the external sounder
and detection devices that require 12V power, e.g., moment
sensors. The auxiliary output is protected by an auto resetting fuse
(PTC) rated at 1.1 Amp).
6. Panel Outputs 1 to 4
These are fully programmable high current (1 Amp), switched
negative supervised outputs. Panel outputs 1 and 2 default to bell
and strobe operation, but can be programmed for other functions if
required, see page 31 for programming details. Each output can also
be programmed for supervision monitoring, see page 25.
Panel output 4 defaults as speaker driver and is used for drivi
ng 16Ω
extension loudspeakers (see page 12). If a loudspeaker driver is not
required it can be used as a standard output.
7. RhinoBus Port
The Rhino bus terminals provide connection to Rhino
communication modules.
8. COM Port 1 & 2
COM 1 is provided for local downloading and for third party devices.
COM2 is in parallel with the RhinoBus Port (7) and provides a
different method of connecting compatible modules.
9. Power/Status LED
On steady when either AC or standby battery is present. Flashes
when the communicator is sending data.
10. Lid Tamper Connector
This connector can be used to connect a lid tamper switch to
provide protection for when the enclosure cover is opened.
11. Antenna Screw Connector
This connector provides a screw in connection for the on-board
wireless transceiver antenna.
12. Battery Connections
A 12V rechargeable battery must be connected to these two
terminals in order to provide continuous system operation in the
event of mains failure. The battery output is protected by an auto
resetting fuse (PTC) rated at 1.6 Amp.