16
FSK-RAP816-V2015.04
3.
Programming the Control Panel
Introduction
This section covers the system programming and it is important that
all engineers read this section carefully so as to familiarise
themselves with the many features and functions of the control
panel. To access the programming menu, enter the factory default
engineer code
789000
. If a mistake is made whilst entering the
code, simply re-enter the code correctly.
The system configuration and programming is broken down into
two modes:
Easy Mode
This mode allows access to the most common programmable
features. The following easy modes are available:
1: Zone Configuration
2: Area Configuration
3: Keypads
4: Outputs
5: Users
Expert Mode
This mode allows access to all programmable features. When Expert
Mode is selected from the main menu, each programming option is
accessed by a four digit location number followed by
Enter
. The
location numbers have been grouped together into logical sections.
The programming sections are as follows:
Section
Page
1 Zone Programming
1
Zone Types
2
Wiring
3
Zone Attributes
4
Reserved
5
Bypass Options
6
Chime Options
7
Soak Test
8
Zone Text
9
Zone Links
19
2 Area Options
1
Area 1 Options
2
Area 2 Options
22
3 System Configuration
1
System Timers
2
System Counters
3
Hardware Options
4
Configuration
5
Control Timers
6
Banner Text
7
Reserved
8
Reserved
9
System Output Links
24
Section
Page
4 Keypad Options
11
Keypad Options 1
12
Keypad Options 2
13
Keypad Sounds
14
Keypad Areas
28
5 Expander Options
10
Expander Areas
11
Expander Options
12
Expander Sounds
2
Expander Output Type
3
Expander Output Attributes
4
Expander Output Areas
5
Expander Output Link
29
6 System Outputs & Devices
1
Panel Outputs
2
Com Ports
3
GSM Configuration
4
TCP/IP Configuration
31
7 Communicator (Optional)
0
ARC 1 - 4 Configuration
1
Options
2
Reserved
3
Reserved
4
UDL Options
35
8 Users
1
User Code
2
User Type
3
User Time Locks
4
User Name
5
User Link
6
User Areas
37
9 Utilities
0
Set Time and Date
38
Exiting Engineer
’
s Program Mode
To exit the engineers programming menus and return to the normal
disarmed mode:
f
From Easy Mode, ensure the display is showing the main
menu. Press
Clear
to select “Exit Menu” then
Enter
to exit the
engineer’s program mode.
f
From Expert Mode, ensure the display is prompting you for a
location number, Press
99 Enter
to
exit the engineer’s
program mode.
Содержание RHINO 816
Страница 1: ......
Страница 4: ...4 FSK RAP816 V2015 04 1 System Overview System Configuration ...
Страница 45: ...FSK RAP816 V2015 04 45 ...
Страница 50: ...50 FSK RAP816 V2015 04 Technical Support Email techadmin fsk co za ...
Страница 51: ......