Locations:
1801
to
1816
Zone 01 to 16: Zone Text.
Entry Mode:
Enter 4 digit location followed by
Enter
, then use
keys to enter text, see page 17. When finished press
Enter
to accept
or
Clear
to cancel.
Zone Link
Each zone can be assigned a
“Link” number
, which in turn is used to
control “Link Control” output types, for details on link control, see
page 33.
Locations:
1901
to
1916
Zone 01 to 16: Zone Link.
Entry Mode:
Enter 4 digit location followed by
Enter
, then key
in 3 digit zone link number. When finished press
Enter
to accept or
Clear
to cancel.
When the zone link is programmed from 001 to 099 or
101 to 199 the link functions as an input and zone activity
will affect the relevant “Link Control” output. When the
zone link is programmed from 201 to 255 the zone link
functions as an output which is mapped to the wireless
device that is associated with the zone. For example, if a
MS1 Wireless Mains Switch has been learnt to zone 11
and the “Zone 11 Link” is programmed as 201. The MS1 is
controlled via “Link Control 01, see link control on page
33.
2. Area Options
This section covers programming of the arming modes, timers and
options for areas 1 and 2.
Area Timers
Each arming mode has its own set of timers that are used to control
various delays during arming, disarming and in alarm.
Locations:
2101
to
2106
Area 1: Timers 01 to 06.
2201
to
2206
Area 2: Timers 01 to 06.
Entry Mode:
Enter 4 digit location followed by
Enter
, then key
in 3 digit timer value. When finished press
Enter
to accept or
Clear
to cancel.
01 Exit Delay
When the Arming Mode is configured as Timed or deferred, this
timer sets the delay between the user initiating the exit procedure
and the system actually arming. Default = 30 seconds.
02 Entry 1 Delay
When the system is armed, activation of a “Final Exit 1” zone will
start the entry 1 delay timer, this allows the user time to access the
remote keypad and disarm the system. Default = 10 seconds.
03 Entry 2 Delay
When the system is armed, activation of a “Final Exit 2” zone will
start the entry 2 delay timer, this allows the user time to access the
remote keypad and disarm the system. Default = 20 seconds
04 Second Entry
If at the end of normal entry (Entry 1 or 2) delay, the system has not
been disarmed, the system will start the second entry delay, during
this time the internal alarm tone will sound. If at the end of the
second entry delay the system has still not been disarmed, a full
alarm is generated. Default = 0 seconds.
05 Bell Delay
When an alarm is generated, this timer is used to delay the
activation of the external sounder and strobe. Default = 0 minutes
06 Bell Duration
When an alarm is generated, this timer is used to control the active
duration of the external sounder and strobe. Default = 2 minutes
Area Arming Modes
This set of options control how the selected area is armed for both
the “Away” and “Stay” arming mode.
Default arming mode for all
areas is Timed Exit.
Locations:
2131
- Area 1 Away Arm Mode.
2231
- Area 2 Away Arm Mode.
2132
- Area 1 Stay Arm Mode.
2232
- Area 2 Stay Arm Mode.
Entry Mode:
Enter 4 digit location followed by
Enter
, then key
in a 1 digit arming mode option from list below or press
i
to scroll
through list. When finished press
Enter
to accept or
Clear
to cancel.
0
Final Exit
When the exit mode is started, the selected area will only arm after
the activation of a Final Exit 1 or Final Exit 2 zone type, e.g., after the
front door is opened the closed.
1
Timed Exit
When the exit mode is started, the selected area will arm after the
Exit Delay timer has expired.
2
Exit Terminator
When the exit mode is started, the selected area will only arm after
activation of a Final Exit 1 or Final Exit 2 zone type, followed by the
activation of an Exit terminator zone, e.g., after the front door is
opened then closed and the push to set button has been pressed.
3
Deferred
When the exit mode is started, the selected area will arm after the
Exit Delay timer has expired. However, if a zone off the exit route is
activated during this period, the Exit Delay timer is suspended whilst
the zone is active.
Area Configuration Options 1
This first set of configuration options controls the operation of each
area. Default configuration settings are shown in bold and are the
same for both areas.
Locations:
2141
- Area 1 Configuration Options 1.
2241
- Area 2 Configuration Options 1.
Entry Mode:
Enter 4 digit location followed by
Enter
, then use
keys
1
to
8
to toggle options from the list below on or off. When
finished press
Enter
to accept or
Clear
to cancel.
1
Arming with AC off
On: The selected area can be armed when the mains supply is
switched off.
Off: The selected area cannot be armed when the mains supply is
switched off.