36
FSK-RAP816-V2015.04
The call attempts are controlled by how many digits are entered. For
example,
“
4343
” = Attempt to c
all the selected ARC four times
alternating between FSK Gateway and IP Module.
ARC 1-4: Reported Event Groups
This set of options allows you to control which group of events that
are reported for each ARC.
Locations:
7051
to
7054
ARC 1 to 4: Reported Event Groups.
Entry Mode:
Enter 4 digit location followed by
Enter
, then use
keys
1
to
7
to toggle options from the list below on or off. When
finished press
Enter
to accept or
Clear
to cancel.
1
Alarms
On: The selected ARC reports events that are assigned in the
alarm group.
Off: The selected ARC does not report alarm events.
2
Tampers
On: The selected ARC reports events that are assigned in the
tamper group.
Off: The selected ARC does not report tamper events.
3
Faults
On: The selected ARC reports events that are assigned in the fault
group.
Off: The selected ARC does not report fault events.
4
Open/Close
On: The selected ARC reports events that are assigned in the
open/close group.
Off: The selected ARC does not report open/close events.
5
Test/Misc.
On: The selected ARC reports events that are assigned in the
test/misc. group.
Off: The selected ARC does not report test/misc. events.
6
Restore
On: The selected ARC reports events that are assigned in the
restore group.
Off: The selected ARC does not report restore events.
7
Custom
On: The selected ARC reports events that are assigned in the
custom group.
Off: The selected ARC does not report custom events.
ARC 1-4: Cancel on Success
This set of options allows you to control communication sequence
for each ARC. When the communicator is triggered by an event it
will call the ARC using the settings defined in ARC 1. If the
communication attempt is successful, this option can be used to
either cancel attempts for the remaining available ARC
’s
or move on
and call the next available ARC.
Locations:
7061
to
7064
ARC 1 to 4: Cancel on Success.
Entry Mode:
Enter 4 digit location followed by
Enter
, then use
keys
1
to
7
to toggle options from the list below on or off. When
finished press
Enter
to accept or
Clear
to cancel.
1
Stop ARC 1
On: The selected ARC will cancel further attempts to ARC 1 after a
successful communication.
Off: The selected ARC will move on to next ARC after a successful
communication.
2
Stop ARC 2
On: The selected ARC will cancel further attempts to ARC 2 after a
successful communication.
Off: The selected ARC will move on to next ARC after a successful
communication.
3
Stop ARC 3
On: The selected ARC will cancel further attempts to ARC 3 after a
successful communication.
Off: The selected ARC will move on to next ARC after a successful
communication.
4
Stop ARC 4
On: The selected ARC will cancel further attempts to ARC 4 after a
successful communication.
Off: The selected ARC will move on to next ARC after a successful
communication.
ARC 1-4: Areas
This option controls which areas report events to the ARC.
Locations:
7071
to
7072
ARC 1 to 2: Areas.
Entry Mode:
Enter 4 digit location followed by
Enter
, then use
keys
1
to
2
to toggle area 1 or 2 on or off. When finished press
Enter
to accept or
Clear
to cancel.
ARC 1-4: IP Address
This option allows an IP address to be programmed for each ARC.
Locations:
7081
to
7084
ARC 1 to 4: IP Address.
Entry Mode:
Enter 4 digit location followed by
Enter
, then key
in the IP Address,
press Bypass then 3
to
insert a “.”. When
finished press
Enter
to accept or
Clear
to cancel.
ARC 1-4: IP Port Number
This option allows an IP port number to be programmed for each
ARC.
Locations:
7091
to
7094
ARC 1 to 4: IP Port Number.
Entry Mode:
Enter 4 digit location followed by
Enter
, then key
in the IP port number. When finished press
Enter
to accept or
Clear
to cancel.
Options: Auto Test Call Period
The communicator can be programmed to send a test call event to
the ARC. This option controls the period in hours in which a test call
is sent. The test call timer is reset every time a system event is
successfully communicated, therefore a test call will only be sent
once the timer reaches zero.
Location:
7101
Entry Mode:
Enter 4 digit location followed by
Enter
, then key
in a 3 digit test call period. When finished press
Enter
to accept or
Clear
to cancel.