RH-806 Wireless Key Fob
Each user maybe assigned a wireless key fob to allow remote
control of the system. The figure below shows the layout of the key
fob:
Standard Remote Control
Beep Remote Control
1. Panic Alarm
This button activates the panic alarm.
2. Away Arm
This button Away Arms the areas allocated to the user
3. Disarm
This button disarms the areas allocated to the user.
4. Stay Arm
This button stay arms the areas allocated to the user.
5. Remote Control 1
This button toggles on and off outputs that are programmed as
“Remote Control 1.
6. Remote Control 2
This button toggles on and off outputs that are programmed as
“Remote Control 2.
7. Activity LED
The activity LED illuminates when the key fob is transmitting a
wireless signal.
Commissioning
Once ALL connections have been made to the control panel and
power is ready to be applied, you should read this section before
continuing.
The control panel leaves the factory programmed with default
settings and when the system is powered up for the first time the
default settings are in use. If the factory defaults need to be
reloaded in future,
press “CLEAR, 9
then ENTER
” on the graphic
LCD keypad within 10 seconds after powering up the panel.
f
Connect the black battery lead to the negative (
–
) terminal of
the standby battery and the red battery lead to the positive (+)
terminal of the standby battery. The green power LED on the
main PCB will light.
f
If the system enters into an alarm condition, enter the default
master user code
1234
. The alarm tone will then stop.
f
To access the Engineer Programming Menu, enter the default
engineer code
789000
. The remote keypads will show:
f
Program the system as described in the next section
(Programming the Control Panel).
f
Carry out a walk test as described on page 39. Remember that
some powered detectors (e.g. PIRs and combined technology
detectors) take several minutes to warm up before they
become operational.
f
Replace the lid and secure with the lid screw supplied - do not
over-tighten.
f
Press
Clear
to
select “Exit Menu” then
Enter
to exit the
engineer’s
program mode.
Installation is now complete and the system is ready for use. Please
ensure the system users are provided with adequate training on
operating the alarm system.