FSK-RAP816-V2015.04
23
2
Reserved
Do not use this option.
3
Auto Stay Arm
On: The selected area automatically performs a Stay Arm, if the
user does not activate a Final Exit zone.
Off: The selected area will always perform an Away Arm.
4
Silent Exit
On: The selected area exit tone remains silent during exit mode.
Off: The selected area exit tone is generated during exit mode.
5
Local Exit Tone
On: If the exit tone is enabled, the exit tone is only generated
from the remote keypad that was used arm the selected
area.
Off: If the exit tone is enabled, the exit tone is generated from all
devices assigned to selected area.
6
Anti-Masking when Armed
On: Anti-Masking faults are only monitored when the selected area
is armed.
Off: Anti-Masking faults are monitored at all times for the
selected area.
7
Bell on Arm Fail
On: If the selected area fails to arm, the external sounder and
strobe is activated.
Off: The external sounder and strobe are not activated.
8
Pulse Strobe on Arm
On: When the selected area is armed successfully, the external
strobe is activated for 5 seconds.
Off: The external strobe is not activated.
Area Configuration Options 2
This second set of configuration options controls the operation of
each area.
Locations:
2142
- Area 1 Configuration Options 2.
2242
- Area 2 Configuration Options 2.
Entry Mode:
Enter 4 digit location followed by
Enter
, then use
keys
1
to
7
to toggle options from the list below on or off. When
finished press
Enter
to accept or
Clear
to cancel.
1
Only Exit when Ready
On: The exit mode can only be started if all zones are healthy
(System Ready) for the selected area.
Off: The exit mode can be started even if one or more zones are
active. The active zones will be indicated on the remote
keypads and a fault tone is generated.
2
Reserved
Do not use this option.
3
Alarms are Engineer Reset
On: Intruder alarms generated in the selected area require an
engineer to reset the system back to normal.
Off: Intruder alarms in the selected area can be reset by users.
4
Enable Bell Squawk
On: The bell output is pulsed once for a very short period when the
selected area is armed and twice when disarmed.
Off: The bell output operates as normal for the selected area.
5
Enable Walk Squawk
On: The bell output is pulsed once for a very short period when a
zone is activated during a walk test in the selected area.
Off: The bell output operates as normal for the selected area.
6
Reserved
Do not use this option.
7
Chime = Link 99
On: The chime feature is automatically turned on and off by Link
Control 99.
Off: The chime feature must be turned on or off by the user.
Area Configuration Options 3
This second set of configuration options controls the operation of
each area.
Locations:
2143
- Area 1 Configuration Options 3.
2243
- Area 2 Configuration Options 3.
Entry Mode:
Enter 4 digit location followed by
Enter
, then use
keys
1
to
7
to toggle options from the list below on or off. When
finished press
Enter
to accept or
Clear
to cancel.
1
Silent Arm
On: The exit tone remains silent during exit mode, when a
keyswitch is used to arm the selected area.
Off: The exit tone is generated during exit mode, when a
keyswitch is used to arm the selected area.
2
Disabled when Armed
On: The keyswitch is disabled when selected area is armed (arm
only keyswitch).
Off: The keyswitch remains enabled when the selected area is
armed.
3
Instant Arm
On: The selected area is armed instantly when a keyswitch is
used.
Off: The area exit mode is used to arm the selected area.
4
Disable Bell when Stay Armed
On: The bell is disabled when the select area is stay armed.
Off: The bell is enabled when the select area is stay armed.
5
Disable Bell when Disarmed
On: The bell is disabled when the select area is disarmed.
Off: The bell is enabled when the select area is disarmed.
6
Disable Comms when Disarmed
On: The communication (PSTN/GSM) is disabled when the select
area is disarmed.
Off: The communication is enabled when the select area is
disarmed.
7
Enable Auto Arm
On: The area is automatically armed using either system timer 22
or 23, see page 25.
Off: The area is not automatically armed.
Area Timer Control
This set of options controls how the system Control Timers can be
used to automatically arm/disarm the selected areas at specific
times and on specific days of the week. Please refer to page 27 for
details on Control Timer configuration.
Locations:
2151
- Area 1 Timer Control.
2251
- Area 2 Timer Control.
Entry Mode:
Enter 4 digit location followed by
Enter
, then use
keys
1
to
7
to toggle options from the list below on or off. When
finished press
Enter
to accept or
Clear
to cancel.
1
Arm with Control Timer 1
On: The selected area is automatically armed by Control Timer 1.