32
FSK-RAP816-V2015.04
No
Type & Description
0007
Bell Active
This output type activates when an alarm is generated (it may
be delayed if the bell delay time is greater than zero). The
duration of this output type is controlled by the “Bell Duration”
timer.
0008
Strobe Active
This output type activates when an alarm is generated and
deactivates when the system is reset
0009
Alarm
This output type activates when an intruder alarm is
generated.
0010
Confirmed Alarm
This output type activates when two different zones cause an
intruder alarm.
0011
Alarm Abort
This output type activates when the user disarms the system
after an alarm and within the “Abort Delay” period.
0012
Fire Alarm
This output type activates when a fire alarm is generated.
0013
PA Alarm
This output type activates when a panic alarm is generated.
0014
Duress Alarm
This output type activates when a duress alarm is generated.
0015
24hr Alarm
This output type activates when a 24hr alarm is generated.
0016
Medical Alarm
This output type activates when a medical alarm is generated.
0017
Tamper Alarm
This output type activates when a tamper alarm is generated.
0018
Ready
This output type activates when the system is ready for
arming, i.e. all zones are healthy.
0019
Trouble
This output type activates when a trouble alarm is generated.
0020
Alert
This output type activates when an alert event is generated
and deactivates when the user has acknowledged the alert.
0021
Zone Bypass
This output type activates when one or more zones are
bypassed.
0022
In Walk Test
This output type activates when the user walk test mode is
selected.
0023
Flash 1 Second
This output type continually pulses on and off at a rate of 1
second.
0024
User Test Active
This output type activates when the user test mode is selected
in the “Bell Test” menu.
0025
Reserved
This output type is reserved for future use.
0026
Reserved
This output type is reserved for future use.
0027
Reserved
This output type is reserved for future use.
0028
Battery Fault
This output type activates when a fault is detected with the
control panel standby battery.
0029
Box Tamper Fault
This output type activates when the control panel box tamper
is open.
No
Type & Description
0030
Bell Tamper Fault
This output type activates when the control panel bell tamper
is open.
0031
Engineer on Site
This output type activates when the engineer is logged on.
0032
Detector Reset
This output type is normally active and is used for powering
devices that require their power supply to be removed in order
to reset them. The output deactivates for 5 seconds at the
start of exit mode and when the system is reset.
0033
Detector Latch
This output type is used to latch the alarm condition on
detection devices that have a latch input.
0034
System Low Volts
This output type activates when a low voltage fault is detected
with the control panel standby battery.
0035
In Exit
This output type activates when the system is in exit mode.
0036
In Entry
This output type activates when the system is in entry mode.
0037
In Second Entry
This output type activates when the system is in second entry
mode.
0038
In Alarm
This output type activates when any alarm is generated.
0039
Auxiliary Alarm
This output type activates when an auxiliary alarm is
generated.
0040
Warning Alarm
This output type activates when a warning alarm is generated.
0041
Keypads Locked
This output type activates when a security key is active.
0042
Output Fault
This output type activates when a fault is detected on one of
the monitored control panel outputs.
0043
Call Engineer
This output type activates when the system requires an
engineer access code in order to reset the system.
0044
Device Fault
This output type activates when a device fault is detected.
0045
Service Required
This output type activates when the service timer expires.
0046
Cleaner Bypassed
This output type activates when
a “
Cleaner
Bypass” is in
voked.
0047
N/A
Not available on the Rhino 816.
0048
N/A
Not available on the Rhino 816.
0049
N/A
Not available on the Rhino 816.
0050
User/Door Access
This output type activates for 30 seconds when any valid user
code is entered.
0051
Alarm Test
This output type activates when the user select the alarm
sounder test.
0052
Panel AC On
This output type activates when the mains supply is present.
0053
Reset Active
This output type activates for 10 seconds after a user resets
the system.