Expert Mode Menu Navigation
Expert Mode allows access to all programming options and features.
Each programming location is accessed by entering its four digit
location number followed by
Enter
. If you don’t know the exact
location you can enter less than four digits and the panel will take
you to the first location that starts with numbers you have entered.
For example if you enter
12
the panel will take you to location 1201
–
Zone 01 Wiring Type.
When the panel gets defaulted, configuration settings shown in bold
take effect.
WHEN THE PANEL GETS DEFAULTED, CONFIGURATION
SETTINGS SHOWN IN
BOLD
THROUGHOUT THE MANUAL
TAKE EFFECT.
1. Zone Programming
This section covers programming of the detection zones, each zone
must be programmed a zone type, wiring type and attributes.
DEFAULT CONFIGURATION SETTINGS FOR ZONES WHEN
THE PANEL IS
DEFAULTED BY PRESSING “CLEAR, 9,
ENTER”
ARE SHOWN ON PAGE 44.
Zone Type
Each zone must be programmed to the correct type in order for the
correct response.
Locations:
1101
to
1116
Zone 01 to 16: Zone Type.
Entry Mode:
Enter 4 digit location followed by
Enter
, then key
in 2 digit zone type from list below or press
i
to scroll through list.
When finished press
Enter
to accept or
Clear
to cancel.
00 Not Used
Use this zone type for unused zones, as zones
programmed as “Not
Used” are not be monitored by the system.
01 Delay 1/Final Exit 1
Use this zone type for the main entry/exit detector, normally a
magnetic contact on the front door. The zone can be activated
during the exit mode without causing a fault. If the system is armed,
activation of the zone will start the Entry 1 Delay timer for the
relevant arm mode.
02 Delay 2/Final Exit 2
Use this zone type for an alternative entry/exit detector. The zone
can be activated during the exit mode without causing a fault. If the
system is armed, activation of the zone will start the Entry 2 Delay
timer for the relevant arm mode.
03 Walk Through
Use this zone type for detection devices along the entry/exit route.
This zone type will allow the user to walk past the detector without
causing a fault during the exit mode or an Intruder alarm during the
entry mode. However, if activated at any other time the zone will
cause an immediate intruder alarm. This zone type will also start the
entry mode when the system is stay armed.
04 Intruder
Use this zone type for detection devices such as PIR’s, vibration
detectors, magnetic door contacts etc. This zone type generates an
intruder alarm if activated when the system is armed.
05 Perimeter
Use this zone type f
or detection devices such as external PIR’s, IR
beams. This zone type generates an intruder alarm if activated when
the system is armed.
06 Fire
Use this zone type for smoke and heat detectors. This zone type
generates a distinctive fire alarm if activated at any time.
07 PA Silent
Use this zone type for panic buttons. This zone type generates a
silent panic alarm if it is activated at any time.
08 PA Audible
Use this zone type for panic buttons. This zone type generates an
audible panic alarm if it is activated at any time.
09 Medical
Use this zone type for medical alarms. This zone type generates a
medical alarm if it is activated at any time.
10 24 Hour
Use this zone type for detectors that require 24 hour monitoring.
This zone type generates an intruder alarm if it is activated when
the system is armed. If activated during the disarmed state an
internal alarm is generated.
11 Tamper
Use this zone type for tamper protection. This zone type generates a
tamper alarm if it is activated when the system is armed. If activated
during the disarmed state an internal alarm is generated.
12 Exit Terminator
Use this zone type for external push to set buttons. This zone type
terminates the exit delay when activated during exit mode. The
arming mode must be configured f
or “Exit Terminator” for this zone
type to function.
13 Away Arm Key
Use this zone type for a key switch or lock that has switch contacts.
This zone type will away arm the assigned areas when active and
disarm the assigned areas when healthy. If a “momentary”
operation is required then the “Momentary Keyswitch” attribute
can be assigned, see page 21.
14 Stay 1 Arm Key
Use this zone type for a key switch or door lock that has switch
contacts. This zone type will stay arm (1) the assigned areas when
active and disarm the assigned areas when healthy. If a