24
FSK-RAP816-V2015.04
Off: The selected area is not armed automatically.
2
Arm with Control Timer 2
On: The selected area is automatically armed by Control Timer 2.
Off: The selected area is not armed automatically.
3
Arm with Control Timer 3
On: The selected area is automatically armed by Control Timer 3.
Off: The selected area is not armed automatically.
4
Arm with Control Timer 4
On: The selected area is automatically armed by Control Timer 4.
Off: The selected area is not armed automatically.
5
Disarm with Control Timer 1
On: The selected area is automatically disarmed by Control Timer
1.
Off: The selected area is not disarmed automatically.
6
Disarm with Control Timer 2
On: The selected area is automatically disarmed by Control Timer
2.
Off: The selected area is not disarmed automatically.
7
Disarm with Control Timer 3
On: The selected area is automatically disarmed by Control Timer
3.
Off: The selected area is not disarmed automatically.
8
Disarm with Control Timer 4
On: The selected area is automatically disarmed by Control Timer
4.
Off: The selected area is not disarmed automatically.
3. System Configuration
This section covers programming of the system timers, counters,
hardware, control timers, banner text options and links.
System Timers
The system timers control global system timing and delay operation.
Locations:
3101
- AC Fail Delay.
3102
- Reserved.
3103
- Zone Response Time.
3104
- Abort Delay.
3105
- Battery Test Period.
3106
- Battery Test Duration.
3107
- Zone Soak Test Time.
3108
- Double Knock Delay.
3109
- Service Interval.
3110
- Confirmation Period.
3111
- Pulse 1 Time.
3112
- Pulse 2 Time.
3113
- Pulse 3 Time.
3114
- Delay 1 Time.
3115
- Delay 2 Time.
3116
- Delay 3 Time.
3117
- Warning Delay.
3118
- Radio Poll Delay.
3119
- Random Min Time.
3120
- Random Max Time.
3121
- Access Time.
3122
- Keyswitch Auto Re-arm Time.
3123
- Auto Re-arm Time.
Entry Mode:
Enter 4 digit location followed by
Enter
, then key
in 3 digit timer value. When finished press
Enter
to accept or
Clear
to cancel.
01 AC Fail Delay
This timer is used to delay (0-255 minutes) the audible annunciation
from the keypads and internal sounders following an AC mains
failure. Default = 30 minutes.
02 Reserved
Do not use
03 Zone Response Time
This timer is used to control the response (0-255 x 10ms) of zones
programmed with the “Fast Response” attribute.
Default = 750
milliseconds.
04 Abort Delay
This timer is used to control abort delay period (0-255 x seconds).
When an intruder alarm is generated, this timer is started and if the
system is disarmed befor
e the timer expires an “Alarm Abort” event
is generated. This event can be signalled to the alarm receiving
centre. Default = 180 seconds.
05 Battery Test Period
This timer is used to control frequency (0-255 hours) at which the
standby battery is load tested. Default = 24 hours.
06 Battery Test Duration
This timer is used to control the duration (0-255 seconds) of the
standby battery load test. Default = 10 seconds.
07 Zone Soak Test Time
This timer is used to control the duration (0-255 days) of the zone
soak test. The timer is automatically started after a zone is put on
test. Default = 14 days.
08 Double Knock Delay
This timer controls the duration (0-255 seconds) of the double
knock delay. The double knock delay is used to control the
operation of zones
programmed with “Double Knock” attribute, see
page 20. Default = 30 seconds.
09 Service Interval
This timer controls the frequency (0-
255 weeks) in which a “Service
Required” event is generated. Default = 0 weeks.
10 Confirmation Period
This timer controls the duration (0-255 minutes) in which a
confirmed alarm event can be generated. When the system is
armed and an intruder alarm is generated (first alarm), this timer is
started. If a second, but different zone activates an intruder alarm
before the timer expires, a confirmed alarm event is generated.
Default = 45 minutes.
11 Pulse 1 Time
This timer controls the active duration (0-255 seconds) of outputs
programmed with the “Pulse 1” attribute. Default = 10 seconds.
12 Pulse 2 Time
This timer controls the active duration (0-255 seconds) of outputs
programmed with the “Pulse 2” attribute. Default = 30 seconds.