OCTAL T1/E1/J1 FRAMER/LIU COMBO
76
5:4
LB[1:0]
R/W
00
Framer Loopback Selection
These two READ/WRITE bit fields are used to select any of the follow-
ing loop-back modes for the framer section. For LIU loopback modes,
see the LIU configuration registers.
3
TCI
R/W
0
Transmit Clock Inversion
This READ/WRITE bit field inverts the transmit clock before sampling.
0 - Setting this bit to ‘0’ will allow transmit data transition to occur at the
positive edge of the transmit clock.
1 - Setting this bit to ‘1’ will allow transmit data transition to occur at the
negative edge of the transmit clock.
2
RCI
R/W
0
Receive Clock Inversion
This READ/WRITE bit field inverts the receive clock before sending.
0 - Setting this bit to ‘0’ will allow receive data transition to occur at the
positive edge of the receive clock.
1 - Setting this bit to ‘1’ will allow receive data transition to occur at the
negative edge of the receive clock.
T
ABLE
12: L
INE
I
NTERFACE
C
ONTROL
R
EGISTER
R
EGISTER
1 - T1/E1 M
ODE
L
INE
I
NTERFACE
C
ONTROL
R
EGISTER
(LICR) H
EX
A
DDRESS
: 0
X
n101
B
IT
F
UNCTION
T
YPE
D
EFAULT
D
ESCRIPTION
-O
PERATION
LB[1:0]
T
YPES
O
F
L
OOP
B
ACK
S
ELECTED
00
No LoopBack
01
Framer Local LoopBack is enabled. When framer local
loopback is enabled, the transmit PCM input data is
looped back to the receive PCM output data. The
receive input data at RTIP/RRING is ignored while an
All Ones Signal is transmitted out to the line interface.
10
Framer Far-End (Remote) Line LoopBack is enabled.
When framer remote loopback is enabled, the digital
data enters the framer interface, however does not
enter the framing blocks. The receive digital data from
the LIU is allowed to pass through the LIU Decoder/
Encoder circuitry before returning to the line interface.
11
Framer Payload LoopBack is enabled. When framer
payload loopback is enabled, the raw data within the
receive time slots are looped back to the transmit
framer block where the data is re-framed according to
the transmit timing.