XRT86VL38
PRELIMINARY
xr
OCTAL T1/E1/J1 FRAMER/LIU COMBO
REV. P1.0.6
311
4.6
T1/E1 Serial PCM Interface
The most common mode is the standard serial PCM interface. Within this mode, only the serial data, serial
clock, frame pulse and multi-frame pulse are required for both the transmit and receive paths. For the transmit
path, only TxSER is a dedicated input to the device. All other signals to the transmit path in Figure 17 can be
programmed as either input or output. For the receive path, only RxSER and RxMSYNC are dedicated outputs
from the device. All other signals in the receive path in Figure 18 can be programmed as either input or output.
F
IGURE
17. T
RANSMIT
T1/E1 S
ERIAL
PCM I
NTERFACE
F
IGURE
18. R
ECEIVE
T1/E1 S
ERIAL
PCM I
NTERFACE
F
TS1
TxSER
TxSERclk
(bi-directional)
TxSYNC
(bi-directional)
TxMSYNC
(bi-directional)
TS2
TS24
N :
TxMSYNC = 4 * (TxSYNC)
SF :
TxMSYNC = 12 * (TxSYNC)
T1DM :
TxMSYNC = 12 * (TxSYNC)
SLC-96 :
TxMSYNC = 12 * (TxSYNC)
ESF :
TxMSYNC = 24 * (TxSYNC)
TS1
TxSERclk
(bi-directional)
TxSYNC
(bi-directional)
TxMSYNC
(bi-directional)
TS2
TS32
TxMSYNC = 16 * (TxSYNC)
TxSER
T1
E1
F
TS1
RxSER
RxSERcl
k
(bi-directional)
RxSYNC
(bi-directional)
RxCRCSYNC
TS2
TS24
N :
RxCRCSYNC = 4 * (RxSYNC)
SF :
RxCRCSYNC = 12 * (RxSYNC)
T1DM :
RxCRCSYNC = 12 * (RxSYNC)
SLC-96 :
RxCRCSYNC = 12 * (RxSYNC)
ESF :
RxCRCSYNC = 24 * (RxSYNC)
TS1
RxSERcl
k
(bi-directional)
RxSYNC
(bi-directional)
RxCASYNC
TS2
TS32
RxCASYNC = 16 * (RxSYNC)
RxSER
T1
E1