Figure 46 below shows the timing diagram of the output signals associated with the DS1 Receive Overhead
Output Interface module in N or SLC®96 framing format mode.
6.2.4
Configure the DS1 Receive Overhead Output Interface module as destination of the Remote
Signaling (R) bits in T1DM framing format mode
The R bits in T1DM framing format mode can be extracted to:
•
DS1 Receive Overhead Output Interface Block
•
DS1 Receive HDLC Controller
•
DS1 Receive Serial Output Interface.
The Receive Data Link Source Select bits of the Receive Data Link Select Register (RDLSR) controls the
destination of R bits in T1DM framing format mode. The table below shows configuration of the Receive Data
Link Source Select bits of the Receive Data Link Select Register (RDLSR).
If the Receive Data Link Source Select bits of the Receive Data Link Select Register are set to 10, the Receive
Overhead Output Interface Block outputs the R bits extracted from the incoming T1 data stream. Since R bit
presents in Timeslot 24 of every T1DM frame, therefore, bandwidth of T1DM data link channel is 8KHz.
F
IGURE
46. DS1 R
ECEIVE
O
VERHEAD
O
UTPUT
I
NTERFACE
T
IMING
IN
N
OR
SLC®96 F
RAMING
F
ORMAT
MODE
RECEIVE DATA LINK SELECT REGISTER (RDLSR) (ADDRESS = 0XN10AH)
B
IT
N
UMBER
B
IT
N
AME
B
IT
T
YPE
B
IT
D
ESCRIPTION
1-0
Receive Data Link
Source Select
R/W
00 - The extracted Facility Data Link bits are stored in either the LAPD con-
troller or the SLC
®
96 buffer. At the same time, the extracted Facility Data
Link bits are outputted from the framer through the Receive Serial Data
Output Interface via the RxSer_n pins.
01 - The extracted Facility Data Link bits are outputted from the framer
through the Receive Serial Data Output Interface via the RxSer_n pins.
10 - The extracted Facility Data Link bits are outputted from the framer
through the Receive Overhead Output Interface via the RxOH_n pins. At
the same time, the extracted Facility Data Link bits are outputted from the
framer through the Receive Serial Data Output Interface via the RxSer_n
pins.
11 - The Facility Data Link bits are forced to one by the framer.