xr
PRELIMINARY
XRT86VL38
REV. P1.0.6
OCTAL T1/E1/J1 FRAMER/LIU COMBO
102
T
ABLE
23: T
RANSMIT
S
IGNALING
AND
D
ATA
L
INK
S
ELECT
R
EGISTER
- E1 M
ODE
R
EGISTER
10 - E1 M
ODE
T
RANSMIT
S
IGNALING
AND
D
ATA
L
INK
S
ELECT
R
EGISTER
(TSDLSR) H
EX
A
DDRESS
:0
X
n10A
B
IT
F
UNCTION
T
YPE
D
EFAULT
D
ESCRIPTION
-O
PERATION
7
TxSa8ENB
R/W
0
Transmit Sa8 Enable
This READ/WRITE bit field specifies if the Sa8 bit-field (bit 7 within timeslot 0 of
non-FAS frames) will be involved in the transmission of Data Link Information.
0 = Setting this bit to ‘0’ will configure the Data Link Interface to not use the Sa8
bit-field for data link message transmission. Sa8 bit-field within each outbound
non-FAS frame will be set to 1 if Sa8 is inserted from the transmit serial input.
N
OTE
: Sa8 bit-field can be inserted from either the transmit serial input or register
depending on the Transmit SA Select Register (Register Address: 0xn130) setting
1 = Setting this bit to ‘1’ will configure the Data Link Interface to use the Sa8 bit-
field for data link message transmission.
N
OTE
: The data link interface only uses Sa8 bit field for transmission only if Data
Link source is from HDLC controller (DLSRC = b01 from Register 0xn109) and if
Sa 8 bit field is inserted from the transmit serial input (TxSa8SEL = 0 from Regis-
ter 0xn130).
6
TxSa7ENB
R/W
0
Transmit Sa7 Enable
This READ/WRITE bit field specifies if the Sa7 bit-field (bit 6 within timeslot 0 of
non-FAS frames) will be involved in the transmission of Data Link Information.
0 = Setting this bit to ‘0’ will configure the Data Link Interface to not use the Sa7
bit-field for data link message transmission. Sa7 bit-field within each outbound
non-FAS frame will be set to 1 if Sa7 is inserted from the transmit serial input.
N
OTE
: Sa7 bit-field can be inserted from either the transmit serial input or register
depending on the Transmit SA Select Register (Register Address: 0xn130) setting
1 = Setting this bit to ‘1’ will configure the Data Link Interface to use the Sa7 bit-
field for data link message transmission.
N
OTE
: The data link interface only uses Sa7 bit field for transmission only if Data
Link source is from HDLC controller (DLSRC = b01 from Register 0xn109) and if
Sa 7 bit field is inserted from the transmit serial input (TxSa7SEL = 0 from Regis-
ter 0xn130).
5
TxSa6ENB
R/W
0
Transmit Sa6 Enable
This READ/WRITE bit field specifies if the Sa6 bit-field (bit 5 within timeslot 0 of
non-FAS frames) will be involved in the transmission of Data Link Information.
0 = Setting this bit to ‘0’ will configure the Data Link Interface to not use the Sa8
bit-field for data link message transmission. Sa6 bit-field within each outbound
non-FAS frame will be set to 1 if Sa6 is inserted from the transmit serial input.
N
OTE
: Sa6 bit-field can be inserted from either the transmit serial input or register
depending on the Transmit SA Select Register (Register Address: 0xn130) setting
1 = Setting this bit to ‘1’ will configure the Data Link Interface to use the Sa8 bit-
field for data link message transmission.
N
OTE
: The data link interface only uses Sa6 bit field for transmission only if Data
Link source is from HDLC controller (DLSRC = b01 from Register 0xn109) and if
Sa 6 bit field is inserted from the transmit serial input (TxSa6SEL = 0 from Regis-
ter 0xn130).