21
2121331-04-04/19 (Translation of the original operating instructions)
Operating Instructions
Modular Safety Control System MSC
EN
5.3.3.9. Modules SPM0 – SPM1 – SPM2
TERMINAL
SIGNAL
TYPE
DESCRIPTION
VERSION
1
24 VDC
-
Power supply 24 VDC
-
2
NODE_SEL0
Input
Node selection
Input (
"type B"
as per EN 61131-2)
3
NODE_SEL1
Input
4
GND
-
Power supply 0 VDC
-
5
PROXI1_24V
Output
Connections for the 1st proximity switch
(see Page 29)
Power supply 24 VDC on PROXI1
6
PROXI1_REF
Output
Power supply 24 VDC on PROXI1
7
PROXI1 IN1 (3 WIRES)
Input
PROXI1 NO contact
8
PROXI1 IN2 (4 WIRES)
Input
PROXI1 NC contact
9
PROXI2_24 V
Output
Connections for the 2nd proximity
switch
(see Page 29)
Power supply 24 VDC on PROXI2
10
PROXI2_REF
Output
Power supply 24 VDC on PROXI2
11
PROXI2 IN1 (3 WIRES)
Input
PROXI2 NO contact
12
PROXI2 IN2 (4 WIRES)
Input
PROXI2 NC contact
13
n.c.
-
Not connected
-
14
n.c.
-
15
n.c.
-
16
n.c.
-
Table 9: Modules SPM0 – SPM1 – SPM2
5.3.4. Encoder connections with RJ45 plug connector (SPM1, SPM2)
Pin
SPMTB
SPMH
SPMH
TWISTED *
1
INPUT
n.c.
n.c.
n.c.
2
GND
GND
GND
3
n.c.
n.c.
n.c.
TWISTED *
4
A
A
A
5
A
A
A
6
n.c.
n.c.
n.c.
TWISTED *
7
B
B
B
8
B
B
B
* If twisted-pair cables are used.
Table 10: PIN assignment