133
2121331-04-04/19 (Translation of the original operating instructions)
Operating Instructions
Modular Safety Control System MSC
EN
9.4.2.4. Manual restart (USER RESTART MANUAL)
(max. number = 16, including other RESTART operators)
Using the USER RESTART MANUAL operator the restart signal is saved
as per the following truth table.
Clear
Restart
IN
Q
1
X
X
0
X
X
0
0
0
L
1
Retain memory
0
Rising edge
1
1
0
Falling edge
1
Retain memory
Figure 152: Manual restart
Parameter
Enable Clear: If selected, the memory process can be reset.
9.4.2.5. Monitored restart (USER RESTART MONITORED)
(max. number = 16, including other RESTART operators)
Using the USER RESTART MONITORED operator the restart signal is
saved as per the following truth table.
Clear
Restart
IN
Q
1
X
X
0
X
X
0
0
0
L
1
Retain memory
0
Rising edge
1
1
0
1
Retain memory
Figure 153: Monitored restart
Parameter
Enable Clear: If selected, the memory process can be reset.
9.4.2.6. Macro manual restart (MACRO RESTART MANUAL)
(max. number = 16, including other RESTART operators)
Using the MACRO RESTART MANUAL operator, a logic block selected
by the user can be combined with the manual restart function block
("USER RESTART MANUAL") as per the following truth table:
Clear
Restart
D
Q
1
X
X
0
X
X
0
0
0
L
1
Retain memory
0
Rising edge
1
1
0
Falling edge
1
Retain memory
Figure 154: Macro manual restart
Parameter
Input Logic: Use this option to set the number of logic inputs used (2 to 7).
Select Logic: Permits the selection of the type of operator from the following options: AND, NAND, OR, NOR, XOR, XNOR.
Enable Clear: The memory process can be reset if this option is selected.
Enable Out: Select this option to display intermediate result of the logic.
Содержание MSC
Страница 1: ...EN Operating Instructions Installation and use Modular Safety Control System MSC ...
Страница 171: ......
Страница 173: ......