Operating Instructions
Modular Safety Control System MSC
64
(Translation of the original operating instructions) 2121331-04-04/19
8.4.12. Module AH-FO4SO8
MEANING
LED
RECTIFICA
TION MEASURE
RUN GREEN
IN F
AIL
RED
EXT F
AIL
RED
SEL 0/1 ORANGE
OSSD1/4
RED/GREEN
CLEAR1/4 YELLOW
ST
ATUS 1/8 YELLOW
Internal err
or
OFF
Flashes 2 or 3
times
OFF
Indicates the phys
-
ical addr
ess of the
module
Red
OFF
Ì
Send module to EUCHNER for r
epair
.
Compatibility err
or
OFF
Flashes 5 times
OFF
Flashes 5 times
Flashes 5 times
Flashes 5 times
Ì
Firmwar
e version not compatible
with MSC-CB. Send to EUCHNER for firmwar
e upgrade.
OSSD output err
or
OFF
Flashes 4 times
OFF
Flashes 4 times (only the LED corr
esponding to
the output in the ERROR mode)
OFF
OFF
Ì
If the pr
oblem persists, send module
to EUCHNER for r
epair
.
Err
or during communi
-
cation with base unit
OFF
Flashes 5 times
OFF
OFF
OFF
OFF
Ì
Restar
t system.
Ì
If the pr
oblem persists, send module
to EUCHNER for r
epair
.
Err
or in another
extension module or MSC-CB
OFF
ON
OFF
OFF
OFF
OFF
Ì
Restar
t system.
Ì
Check which module is in the ERROR mode.
Extension module of the same type with the same addr
ess
detected
OFF
Flashes 5 times
Flashes 5
times
OFF
OFF
OFF
Ì
Change addr
ess of the module (see
section NODE_SEL)
ST
ATUS output over
-
load or shor
t cir
cuit
OFF
OFF
ON
OUTPUT
state
CLEAR
Flashing
Ì
Check status output connections
OSSD overload or load connected to 24 VDC
OFF
OFF
ON
Flashing
(only the LED
corr
esponding to
the output in the ERROR mode)
OFF
OUTPUT
state
Ì
Check OSSD output connections
No voltage on OS
-
SD3-OSSD4
OFF
OFF
ON
OSSD3/OSSD4
flashing
OSSD3/OSSD4
flashing
OUTPUT
state
Ì
Connect pin 14 to 24 VDC
Node detection err
or
OFF
Flashes 3 times
OFF
Flashes 3 times
OFF
OFF
OFF
Ì
Send module to EUCHNER for r
epair
Table 57:
Tr
oubleshooting AH-FO4SO8
Figur
e 38:
AH-FO4SO8