Parameter
No.
Description
Setting
Validation
Control
Mode
Function and Meaning
t1
t2
PCON disabled
PCON enabled
PCON disabled
Reference pulse
Pn201
Electronic gear numerator 1
Pn203
Electronic gear numerator 2
Pn201
Electronic gear numerator 1
t1
,
t2>1ms
[1] Corresponding time sequence
Time sequence when Pn002.0=0 or 1
Error time sequence
Pn002.1
Reserved
Pn002.2 Absolute encoder selection
[0] Use absolute encoder as an absolute encoder
[1] Use absolute encoder as an incremental encoder
Pn002.3 Reserved
Pn003
Binary After
restart
ALL
Pn003.0 Reserved
Pn003.1
Reserved
Pn003.2 Low speed compensation
[0] Without low speed correction
[1] With low speed correction to avoid servomotor
creeping, but the degree of correction is
determined by the setting in Pn219.
Pn003.3 Overload enhancement
[0] Without overload enhancement function
[1] With overload enhancement function, which can
enhance the overload capacity when servomotor
exceeds the 2 times rated overload. It is used in
frequent power ON/OFF occasions.
Содержание pronet series
Страница 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Страница 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Страница 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Страница 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Страница 163: ...ProNet Series ACServoUser sManual 161 ProNet 75D 1AD 1ED 2BD Unit mm Air Flow Air Flow Air Flow...
Страница 193: ......