ProNet
Series
AC Servo User's Manual
- 82 -
4.5 Operating Using Speed Control with Analog Reference
4.5.1 Setting Parameters
Parameter Meaning
Pn005
H
.□□0□
Control mode selection:Speed control(analog reference)(factory setting)
Pn300
Speed Reference Input Gain
Setting Range
Setting Unit
Factory Setting
Setting Validation
0
~
3000
rpm/v 150
Immediately
Sets the analog voltage level for the speed reference (V-REF) necessary to operate the servomotor at the rated speed.
■
EXAMPLE
Pn300=150
:
1V input is equivalent to the servomotor speed of 150rpm (factory setting).
Speed
Position
Torque
Содержание pronet series
Страница 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Страница 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Страница 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Страница 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Страница 163: ...ProNet Series ACServoUser sManual 161 ProNet 75D 1AD 1ED 2BD Unit mm Air Flow Air Flow Air Flow...
Страница 193: ......