ProNet
Series
AC Servo User's Manual
- 117 -
4.9 Limiting Torque
The servo drive provides the following three methods for limiting output torque to protect the machine.
NO. Limiting
Method Reference
Section
1
Internal torque limit
4.9.1
2
External torque limit
4.9.2
3
Torque limiting by analog voltage reference
4.9.3
4.9.1 Internal Torque Limit
Maximum torque is always limited to the values set in the following parameters.
Pn401
Forward Torque Limit
Setting Range
Setting Unit
Factory Seeting
Setting Validation
0
~
300
1% 300 Immediately
Pn402
Reverse Torque Limit
Setting Range
Setting Unit
Factory Seeting
Setting Validation
0
~
300
1% 300 Immediately
·
The setting unit is a percentage of rated torque.
·
The maximum torque of the servomotor is used, even though the torque limit is set higher than the maximum torque of
the servomotor. (as is the case with the 300% factory setting)
t
Speed
Maximum torque
t
Speed
Limiting torque
Pn402
Pn401
With No Internal Torque Limit
Maximum torque can be output
With Internal Torque Limit
■
Note:
Too small a torque limit setting will result in insufficient torque during acceleration and deceleration.
Position
Torque
Speed
Position
Torque
Speed
Содержание pronet series
Страница 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Страница 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Страница 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Страница 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Страница 163: ...ProNet Series ACServoUser sManual 161 ProNet 75D 1AD 1ED 2BD Unit mm Air Flow Air Flow Air Flow...
Страница 193: ......